GB

Trouble shooting

Problem

Possible.cause.

Remedy

Washer is

not opera-

ting

ON / OFF switch (5) is turned

off

Check ON / OFF switch

Damaged power supply cable

Check power supply cable (7) for

damage. If necessary have the power

supply cable (7) replaced by a quali-

fied electrician.

Mains fault

Check the electrical system for conformi-

ty with the data on the rating plate.

Washer

does not ge-

nerate any

pressure

Air trapped in the pressure

washer

Turn on the washer with high-pressure

hose until bubble-free water flows out of

the high-pressure connection (3).

Drop in the water mains

pressure

Check the water mains.

Severe

pressure fluc-

tuations

High-pressure nozzle (13) is

dirty

Rinse the high-pressure nozzle (13) with

water. If necessary clean the nozzle

hole with a needle.

Spare Parts Order

When buying parts for the pressure washer, use the service address or fax number given.

Please enter your machine type and the product number of the part you are ordering.

Item. Description........................................................... Product.No.

14

Cleaning agent container with nozzle

...................................

91096764

13

High-pressure nozzle ...........................................................

91096765

1-2 High-pressure hose ..............................................................

91096766

12

Adjustable flat-jet nozzle ......................................................

91096767

11

Jet lance ............................................................................

91096768

10

Gun ..................................................................................

91096769

Advertising
This manual is related to the following products: