Troubleshooting – Enerco HSVFR30LPT User Manual

Page 14

Advertising
background image

14

Installation Instructions and Owner’s Manual

Unvented LP-Gas Vent Free Room Heaters

OBSERVED SYMPTOM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed in, there is

no spark at pilot

1. Ignitor electrode positioned wrong.
2. Ignitor electrode is broken.
3. Ignitor electrode not connected to

ignitor.

4. Ignitor cable pinched or wet.

5. Broken ignitor cable.

6. Bad Piezo ignitor.

7. Low Battery.

1. Reposition electrode
2. Replace electrode
3. Reconnect ignitor cable
4. Free ignitor cable if pinched by any

metal or tubing. Keep ignitor cable dry.

5. Replace ignitor cable
6. Replace control valve
7. Replace battery

ODS/pilot lights but flame goes out when

control knob is released

1. Gas supply turned off or equipment

shutoff valve closed.

2. Control knob not fully pressed in while

pressing ignition button.

3. Air in gas line when installed.

4. ODS/pilot is clogged.

5. Gas regulator setting is not correct

6. Control knob not in pilot position

7. Thermocouple connection loose at

control valve

8. Pilot flame not touching thermocouple,

which allows thermocouple to cool,

causing pilot flame to go out. This

problem could be caused by one or

both of the following:

a. Low gas pressure

b. Dirty or partially clogged ODS/pilot

1. Turn on gas supply turn off or open

equipment shutoff valve closed

2. Fully press in control knob while press-

ing ignition button

3. Continue holding down control knob.

Repeat ignition operation until air is

removed.

4. Clean ODS/pilot (see Cleaning and

Maintenance pages 11 and12).

5. Replace gas regulator
6. Turn Control knob to pilot position

When ignitor button is pressed in, there is

a spark at the ODS/pilot but no ignition

1. Control knob not fully pressed in.

2. Control knob not pressed in long

enough

3. Equipment shutoff valve not fully open

4. Thermocouple damaged

5. Control valve damaged

1. Press in control knob fully

2. After ODS/pilot lights, keep control

knob pressed in for 30 seconds

3. Fully open equipment shutoff valve

4. Hand tighten thermocouple nut until

snug, and then tighten 1/4 turn more.

5. -

a. Contact local gas company

b. Clean ODS/pilot (see Cleaning and

Maintenance, pages 11 and 12).

6. Replace thermocouple

7. Replace Control valve.

TROUBLESHOOTING

NOTE: All troubleshooting items are listed in order of operation and likely occurrence.

WARNING: Only a qualified service person should service and repair heater.

CAUTION: Never use a wire needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit.

Make sure grille guard is in place before running heater. If screen or grille guard is removed for servicing it must be

replaced prior to operating the heater.

WARNING: If you smell gas:

Shut off gas supply

Do not try to light any appliance

Do not touch any electrical switch; do not use any phone in your building

Immediately call you gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remov-

er, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with com-

bustion air and create odors and possible discoloration of walls and ceilings.

Advertising