Introduction

Generator PSE 2800 A1

Q

Introduction

We congratulate you on the purchase of your new
device. You have chosen a high quality product. The
instructions for use are part of the product. They
contain important information concerning safety,
use and disposal. Before using the product, please
familiarise yourself with all of the safety information
and instructions for use. Only use the unit as described
and for the specified applications. If you pass the
product on to anyone else, please ensure that you
also pass on all the documentation with it.

IMPorTAnT!

When using the equipment, a few safety precautions
must be observed to avoid injuries and damage.
Please read the complete operating instructions and
safety information with due care.
We cannot accept any liability for damage or acci-
dents which arise due to a failure to follow these in-
structions and the safety information.

Device description

1

Fuel gauge

2

Petrol cap

3

2 x 230 V∼ sockets

4

Earth connector

5

Petrol filter

6

Overload switch

7

Volt meter

8

Oil fill plug

9

Oil drain plug

10

Low oil trip

11

On / off switch

12

Choke lever

13

Express start

14

Petrol tap

15

Wheels

16

Wheel axle

17

Stand

18

Push bar bracket

19

Push bar

20

Screws M8 x 40

21

Screws M8 x 12

22

Washers for the wheels

23

Safety split pins for the wheels

24

Nuts M8

25

Spark plug socket

26

Oil fill funnel

27

Spark plug

28

Spark plug connector

Intended use

The generator is suitable for devices which use a
230 AC voltage source.
The generator is designed to power electric power
tools and be the power supply for light sources.
Please check the suitability for use of house hold
devices on the manufacturer information.

The machine may only be utilised for its intended use.
Any other use is not intended. The user / operator,
not the manufacturer, is liable for resulting damages
or any type of injury resulting from any other use
that is not intended.

Please ensure that this device was not intended for
commercial use. We do not accept any warranty li-
ability if the device is used for commercial, manual,
or industrial operations, or activities similar to these.

Technical Data

Generator:

Synchronic

Protection type:

IP23M

Continuous output P

rated

(S1):

2600 W

Maximal output P

max

(S2 2 min):

2800 W

Nominal voltage U

rated

:

2 x 230 V∼

Rated current I

rated

:

11.3 A

Frequency F

rated

:

50 Hz

Type drive motor:

4 stroke air-cooled