Maintenance schedule / Warranty

Disposal / Maintenance schedule

Disposal

The packaging is

made of environmentally friendly materi-
als. It can be disposed of at your local
recycling centre.

Do not dispose of

electric equipment in the household waste!

According to European Directive 2012 / 19 / EU,
used electrical devices must be collected and recy-
cled in an environmentally friendly manner.

Contact your local refuse disposal authority for more
details of how to dispose of your worn-out devices.

Troubleshooting guide

Fault

Cause

remedy

Engine does

not start

Automatic oil

cut-out has not

responded

Check oil level,
top up engine oil

Spark plug

fouled

Clean or replace
spark plug
(electrode
spacing 0.6 mm)

No fuel

Refuel / have
the petrol cock
checked

Generator

has too little

or no voltage

Controller or

capacitor

defective

Contact your

dealer

Overcurrent

circuit-breaker

has triggered

Actuate the circuit-

breaker and reduce

the consumers

Air filter dirty

Clean or replace

the filter

Maintenance schedule

Please adhere to the following maintenance periods
in order to ensure a failure-free operation.

IMPOrTANT! The equipment must be
filled with engine oil and fuel before it
is started.

before each

use

After an
operating
period of
20 hours

After an
operating
period of
50 hours

After an
operating
period of
100 hours

After an
operating
period of
300 hours

Checking the

engine oil

X

Changing the

engine oil

For the first

time, then every

50 hours

X

Checking the

air filter

X

Change the

filter insert if

necessary

Advertising