Instruction for the installer, Engineers technical data, Supply connections – Electrolux U30280 35772G User Manual

Page 11: Overall dimensions, Cut out dimensions

Advertising
background image

11

Instruction for the Installer

Engineers technical data

BURNER

RAPID

SEMI-RAPID AUXILIARY

TRIPLE

(large)

(medium)

(small)

CROWN

POSITION

M A X

MIN

M A X MIN

M A X

MIN MAX MIN

NOMINAL THERMAL
POWER (kW)

2.8

0.65

2.0

0.45

1.0

0.33

4.0 1.2

NOMINAL FLOW
RATE (m

3

/h)

0.266

0.062 0.190 0.043 0.095 0.028 0.381 0.114

NOZZLE REFERENCE

113

Adjust.

96

Adjust.

70

Adjust. 146

Adjust.

(1/100 mm)

NOMINAL THERMAL
POWER (kW)

2.8

0.65

2.0

0.45

1.0

0.33

4.0 1.2

NOMINAL FLOW
RATE (g/h)

202

47

144

32

72

24

288 86

NOZZLE REFERENCE

86

40

71

32

50

28

98 56

(1/100 mm)

NATURAL GAS

20 mbar

VALUE =

37.78 MJ/m

3

Ws - 50.7 MJ/ m

3

TYPE OF GAS

LPG GAS

28-30/37 mbar

VALUE =

49.92 MJ/Kg

Burner

Dia. Tap By-pass

1/100 mm

Auxiliary

28

Semi-rapid

32

Rapid

40

Ultra-rapid

56

Aeration adjustment none

Supply Connections

Gas:R 1/2 inch (1/2 inch male) Rear right hand
corner
Electric: 230 V 50 Hz supply, 3 core flexible
cable with non rewireable plug fitted with a 3
amp cartridge fuse.
Heat Input
Ultra-rapid Burner 4.0 kW (13652 BTU/HR)
Rapid Burner

2.8 kW Natural Gas
(10239 BTU/HR)
2.8 kW L.P.G.
(9556 BTU/HR)

Overall dimensions

Width:

680 mm

Depth:

510 mm

Cut out dimensions

Width:

560 mm

Depth:

480 mm

Semi-rapid Burner 2.0 kW (6824 BTU/HR)
Auxiliary Burner

1.0 kW (3413 BTU/HR)

Appliance class

3

Appliance category

II2H3+

Gas supply

Natural gas G 20 / 20 mbar

Advertising