A-27

MIDI Data Format

Filter Cut Off Frequency

NRPN MSB = 01H
NRPN LSB = 20H
Data Entry MSB = mmH
mm .....Cut Off Frequency = 00H to 40H to 7FH (–64 to 0 to

+63)

Recognition

When the instrument receives this message, the preset
Filter Cut off Frequency value for the tone is changed to the
value that corresponds to the data entry MSB of the
received message. There is no change when the value of the
data entry MSB is 40H(0).

Send

This message cannot be sent.

Filter Resonance

NRPN MSB = 01H
NRPN LSB = 21H
Data Entry MSB = mmH
mm .....Filter Resonance = 00H to 40H to 7FH (–64 to 0 to

+63)

Recognition

When the instrument receives this message, the preset
Filter Resonance value for the tone is changed to the value
that corresponds to the data entry MSB of the received
message. There is no change when the value of the data
entry MSB is 40H(0).

Send

This message cannot be sent.

Filter/AMP Envelope Attack Time

NRPN MSB = 01H
NRPN LSB = 63H
Data Entry MSB = mmH
mm .....Filter/AMP Envelope Attack Time = 00H to 40H to

7FH (–64 to 0 to +63)

Recognition

When the instrument receives this message, the preset
Filter/AMP Envelope Attack Time value for the tone is
changed to the value that corresponds to the data entry
MSB of the received message. There is no change when the
value of the data entry MSB is 40H(0).

Send

This message cannot be sent.

Filter/AMP Envelope Decay Time

NRPN MSB = 01H
NRPN LSB = 64H
Data Entry MSB = mmH
mm .....Filter/AMP Envelope Decay Time = 00H to 40H to

7FH (–64 to 0 to +63)

Recognition

When the instrument receives this message, the preset
Filter/AMP Envelope Decay Time value for the tone is
changed to the value that corresponds to the data entry
MSB of the received message. There is no change when the
value of the data entry MSB is 40H(0).

Send

This message cannot be sent.

Filter/AMP Envelope Release Time

NRPN MSB = 01H
NRPN LSB = 66H
Data Entry MSB = mmH
mm .....Filter/AMP Envelope Release Time = 00H to 40H to

7FH (–64 to 0 to +63)

Recognition

When the instrument receives this message, the preset
Filter/AMP Envelope Release Time value for the tone is
changed to the value that corresponds to the data entry
MSB of the received message. There is no change when the
value of the data entry MSB is 40H(0).

Send

This message cannot be sent.