Fill and check fuel level (Fig. 2)

Use mixed petrol (1:50) only. You can use the fuel cap to measure the quantity of the 2-stroke
oil.
 Remove any power cords
 Turn power switches off
 Do not overfill

– do not fill above fuel filter top

 Always screw down fuel cap
 Clean up any spilled fuel
 Do not smoke while operating the generator

Always use caution!

7.3

Starting the generator (Fig. 1)

 Disconnect electric apparatus
 Turn on fuel tap (10).
 Turn on engine switch (2).
 Move choke lever (3) to closed position (to restart a warm engine, leave the choke lever in

open or half-open position).

 Pull slowly on the starter cord until it engages, then pull sharply to start the engine (4).
 Allow the engine to run until it warms up, and then move the choke lever to the open

position (3).

 Plug in the power cord.

7.4

Stopping the generator (Fig. 1)

 Unplug electric apparatus

Turn switch to “OFF” (2)

 Turn off fuel tap (10)

8 SERVICE & MAINTENANCE

8.1

Periodic maintenance

8.1.1

Daily (pre-operation check)

 Check fuel hose for cracks or other damage. Replace if necessary.
 Check choke operation
 Check recoil starter operation

8.1.2

1st Month or 50 hrs

Check condition of spark plug. Adjust gap and clean. Replace if necessary.

8.1.3

3 Months or 150 hrs

 Clean the air filter. Replace if necessary.
 Clean the fuel filter. Replace if necessary.
 Clean the exhaust (decarbonisation). Replace if necessary.

8.2

Service - notes on maintenance

8.2.1

Spark plug inspection (Fig. 3)

 Disconnect the spark plug cap, and remove any dirt from around the spark plug area.
 Remove spark plug (11) with the plug spanner supplied.
 Inspect the spark plug. It should be a tan colour.

Advertising