− there are any leaks.

− the minimum volumetric control (pressure

gauge) is functioning correctly.

− Suction performance check.

A log for annual general inspections should

be kept. This must clearly show the date of

the inspection, identified faults and the name

of the inspector. If required, the machine

should undergo an overhaul!

If required, an overhaul must be carried out.

Written records should be made of the work

carried out during the overhaul.

Repairs to the dust extractor should only

be carried out by qualified technicians!
Elektra Beckum machines requiring repairs

can be sent to the address specified on the

spare-parts list. Please enclose a description

of the fault with the power tool.

Elektra Beckum packaging is 100%

recyclable. Worn-out devices and

accessories contain large amounts of

valuable raw materials and plastics, which

can also be recycled.
These operating instructions are printed on

chlorine-free bleached paper.

Changes due to technological progress

reserved.
Operating mode:

Continuous operation

Current type:

1-phase alternating current

Frequency: 50

Hz

Rated consumption:

P

1

=1.47 kW

Output performance:

P

2

=1.1 kW

Mains voltage:

~230 V

Power consumption:

6.4 A

Degree of protection:

IP 54

Idling speed:

2830 rpm

Diameter of extractor connection piece: 100

mm
Dimensions:

1085 x 655 x 1974 mm

Weight: 97

kg

Filtering surface:

3.45 m

2

Dust collection volume:

135 l

Rated volumetric flow:

V

rat

= 775 m

3

/h

Related vacuum:

2095 Pa

(upstream of ventilator)

Minimum volumetric flow:

V

min

= 565 m

3

/h

Related vacuum:

1572 Pa

(upstream of ventilator)

Max. vacuum:

2430 Pa

Typical A-weighted sound level:

Sound-pressure level:

L

pA

=78 dB(A)

Sound output level:

L

WA

=94 dB(A)

Wear ear protection!

Sound level as per MRL, Appendix 1,

Point 1.7.5 f, in free field, distance 1 m,

height 1.6 m.
Measured values determined in conformity

with EN 23744.
The stated technical specifications are

subject to tolerances (as specified in the

respective current standards).