8.4

Storage

I mportant! Pull the mains plug out of the socket and ventilate the appliance
and all connected pneumatic tools. Switch off the compressor and make
sure that it is secured in such a way that it cannot be started up again by
any unauthorized person.

Important! Store the compressor only in a dry location which is not
accessible to unauthorized persons. Always store upright, never tilted!

9 TECHNICAL DATA

Type

POWX1725

Rated voltage

230 V

Rated frequency

50 Hz

Rated Power

1100 W / 1,5 pk

Rotation speed

3400 min

-1

Rated Pressure

8 bar / 116PSI

Tank capacity

24 l

Air debit (capacity)

180 l/min

Weight

20 kg

10 NOISE

Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA

77 dB(A)

Acoustic power level LwA

97 dB(A)

ATTENTION! Wear hearing protection when sound pressure is over 85
dB(A).

11 POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES

FAULT

CAUSE

REMEDY

The

compressor

does not start

1. No supply voltage

1. Check the supply voltage, the
power plug and the socket-outlet.

2. Insufficient supply voltage

2. Make sure that the extension
cable is not too long. Use an
extension cable with large enough
wires.

3. Outside temperature is too
low

3. Never operate with an outside
temperature of below +5°C.

4. Motor is overheated

4. Allow the motor to cool down. If
necessary, remedy the cause of the
overheating.

The

compressor

starts but there is
no pressure

1. Leak in the non-return
valve

1. Replace the non-return valve

2. The seals are damaged.

2. Check the seals and have any
damaged seals replaced by a service
center