Safety valve, Cleaning and maintenance, Cleaning – Powerplus POWX1750 COMPRESSOR 2200W OIL FREE EN User Manual

Page 8: Maintenance, Technical data, Noise

Advertising
background image

POWX1750

EN

Copyright © 2014 VARO

P a g e

| 8

www.varo.com

As soon as the tank pressure is built up, the motor switches off
automatically.

The motor switches automatically on as soon as the tank pressure
becomes too low.

8.4

Safety valve

The safety valve has been set for the highest permitted pressure of the pressure vessel. It is
prohibited to adjust the safety valve or remove its seal
Actuate the safety valve from time to time to ensure that it works when required. Therefore you
need to remove the protection cover.

9 CLEANING AND MAINTENANCE

9.1

Cleaning

 Keep the safety devices free of dirt and dust as far as possible. Wipe the equipment with a

clean cloth or blow it with compressed air at low pressure.

 We recommend that you clean the appliance immediately after you use it.
 Clean the appliance regularly with a damp cloth and some soft soap. Do not use cleaning

agents or solvents; these may be aggressive to the plastic parts in the appliance. Ensure
that no water can get into the interior of the appliance.

 You must disconnect the hose and any spraying tools from the compressor before

cleaning. Do not clean the compressor with water, solvents or the like.

9.2

Maintenance

The condensation water must be drained off each day by opening the drain valve (ref. 11)

10 TECHNICAL DATA

Type

POWX1750

Rated power

2hp

– 1500W

Current take-off

6.5A

Power supply voltage

220-240 V/50 Hz

Air intake

222l/min

Maximum pressure

10bar (145PSI)

Weight

22,2kg

Tank capacity

50l

Rotation speed

3400 min-1

Protection degree

IP20

11 NOISE

Noise emission values measured according to relevant standard. (K=3)
Acoustic pressure level LpA

77 dB(A)

Acoustic power level LwA

97 dB(A)

ATTENTION! Wear hearing protection when sound pressure is
over 85 dB(A).