Checking the oil-level, Checking the safety valve, Thermal safety – Powerplus POWX1770 COMPRESSOR 2200W 50L LUBRICATED EN User Manual

Page 8

Advertising
background image

POWX1770

EN

Copyright © 2014 VARO

P a g e

| 8

www.varo.com

 Place a receiving bin under the gauge glass.
 Remove the plug from the filling-point.
 Remove the screw from the gauge glass.
 Turn the machine slightly backwards to remove

all oil.

 Re-insert the screw and tighten it securely.
 Fill the pump housing with standard

compressor oil until the level is equal to the dot
on the gauge glass.

 Replace the plug.

8.3

Checking the oil-level

Check the oil-level prior to each use.
 The level must be equal to the red dot on the

gauge glass.

 If the level is below the mark, refill the oil.

8.4

Checking the safety valve

Check the operation of the safety valve prior to each use.

 Make sure that the tank is pressure free. The

pressure gauge must indicate 0 bar.

 Pull the ring a number of times. The pin should

move freely.

Do not use the machine if the pin in the safety valve cannot move freely. Do
not perform any adjustments to the safety valve.

8.5

Thermal Safety

 The machine shuts off automatically in the

event of overheating or overload

 Wait a few minutes to allow the machine to

cool

 Later, you can push the button to begin again

Advertising