12.7

Muffler screen

The engine and muffler will be very hot after the engine has been run.
Avoid touching the engine and muffler while they are still hot with any part of your body or
clothing during inspection or repair.
 Remove the muffler protector and muffler screen.
 Clean the carbon deposits out of the muffler screen using a wire brush.
 Check the muffler screen. Replace it if damaged.
 Install the muffler screen and muffler protector.

13 SERVICE / REPAIRS

 Repairs may be carried out by specialized personnel only. For this, use a specialist

workshop.

 For repairs, only parts may be used which correspond to the original machine details. This

machine contains electrical and mechanical parts which are essential for protection
against sources of danger.

14 TECHNICAL DATA

GENER

A

TOR

Type

Brush

Voltage Regulator

AVR

Max. Output

5500 W

Rated Output

5000 W

AC Voltage

230V

Frequency

50Hz

Phase

single

Power Factor

Cosφ=1.0

Degree of Protection

IP23M

Performance Class

G1

DJ188F

E

N

GI

N

E

Type

Forced air-cooled, 4 cycle, OHV, Gasoline
Engine

Bore×Stroke mm×mm

88x64

Displacement

389CC

Max. Output

13HP/3600rpm

Fuel

Unleaded
EURO 95/98

Fuel tank Capacity

25 liter

Rated Continuous Operation

+/-7.5 hours

Lubricating oil

SAE10W-30

Lubricating oil Capacity

1.1 liter

Starting System

Recoil Starter

Ignition system

T.C.I.

Spark Plug Type

F7RTC

Dimension L×W×H

810x550x580mm

Dry Weight net

82 kg