Cleaning the impeller, Technical data, Service department – Powerplus POWXG9417 SUBMERSIBLE PUMP 750W SS +S ENSOR EN User Manual

Page 5

Advertising
background image

POWXG9417

EN

Copyright © 2014 VARO NV

P a g e

| 5

www.varo.com

Important ! Note!

Remove the mains plug before all maintenance work.

When the pump is often transported in the course of operation, it should be cleaned out
with clear water after every use.

All fibrous particles which may have built-up inside the pump housing should be removed
with a water jet.

Every 3 months the shaft ground and as should be cleaned from mud.

Remove deposits on the floater with clear water.

8.2

Cleaning the impeller

If excessive deposits collect in the pump case you must dismantle the bottom part of the pump
as follows:
1.

Remove the intake cage from the pump case.

2.

Clean the impeller with clear water.

Important! Do not put down or rest the pump on the impeller!
3.

Re-assemble in reverse order

9 TECHNICAL DATA


type

POWXG9417

Voltage / frequency

230V~ 50Hz

Power input

750W

Delivery rate max..

13500 l/h

Delivery height max

7.5 m

Immersion depth max.

max. 7 m

Water temperature max.

35° C

Hose connection

5/4"

Foreign bodies up to

35 mm

Switching point high: ON

16, 20, 24 or, 28cm

Switching point high: OFF

ca. 5 cm

For clean/dirty water:

Dirty

Housing (plastic(P) / Stainless Steel (SS) )

SS

Water inlet (plastic / Stainless Steel (SS) )

SS

Weight

6.81kg

10 SERVICE DEPARTMENT

Damaged switches must be replaced by our after-sales service department.

If the connecting cable (or mains plug) is damaged, it must be replaced by a special
connecting cable which is available from our service department. Replacement of the
connecting cable should only be carried out by our service department (see last page) or
by a qualified specialist (qualified electrician).

Advertising