Model

Ei151TLR Ionisation

Installation & Placement

Wiring for Interconnected Alarms

Be very careful about correctly wiring the alarms as mixing Live and Neutral
will blow/damage interconnected alarms.

Alarms should be placed in accordance with the general guidelines shown in
the diagram above. These recommendations are based on the problem of
areas of “dead air” close to corners of rooms and apexes of ceilings, which
could result in the prevention of smoke reaching the smoke detector

Please consult instruction booklet for specific installation details

Important Precaution:

Do not install the actual smoke/heat
alarm itself in new or renovated
buildings until all work is completed
(including floor coverings) and the
building has been fully cleaned. The
wiring can be installed when
appropriate. (Excessive dust and debris
from building work can contaminate the
smoke chamber and cause problems,
and it will also invalidate the guarantee).
If it must be installed, cover it
completely, particularly around the
edges, with a dust cover (eg. a plastic
bag), until all cleaning is finished..
Connect wires to the unit as in wiring
diagram. All wiring must comply with
local codes.

Technical Specification

Sensor

Ionisation


Sensitivity:

Complies with BS 5446 Part 1:
2000


Source:

Americium 241


Button Test:

Simulates the effect of smoke and
checks electronics and horn.


Supply Voltage:

230V AC


Battery back-up:

Rechargeable lithium cells


Power-On Indicator:

Continuous green LED


Alarm:

Electronic Piezoelectric horn
in unit


Alarm Sound Output:

85dB (minimum) at 3m


Alarm Status:

Red LED flashes every second on

unit sensing fire


Temperature Range:

0° to 40°C


Humidity Range:

15% to 95% Relative Humidity


Remote control:

Ei152, Ei159 or MCP400


Interconnect:

Up to 12 interconnected
Ei150/151TL/151TLR/154TL/155/1
56TLH/156TLR smoke or heat
alarms, along with an EI158 relay
base


Fixing:

Screw fixings supplied


Plastic material:

UL94VO flame retardant


Dimensions:

140mm x 120mm x 46mm


Weight:

227g


Warranty:

5 year (limited) warranty


Approvals:

Kitemarked to BS EN 14604:2005,
CE Approved


Specifications are subject to change