Technical spec i fi ca tions – Eaton Electrical Powerware 5125 User Manual

Page 2

Advertising
background image

Technical Spec i fi ca tions

© 2005 Eaton Corporation
All Rights Reserved
Printed in Australia

5/06 Rev 1

HEAD OFFICE
Eaton Power Quality Pty Ltd
10 Kent Road
Mascot NSW 2020
Phone: +61 2 9693 9366
Fax: +61 2 8338 1159

www.powerware.com.au

Sales 1300 UPS UPS
Service 1300 303 059

SALES OFFICES
Queensland
Phone: +61 7 3891 1211
Fax: +61 7 3891 2492

Victoria
Phone: + 61 3 9706 5662
Fax: + 61 3 9794 9150

South Australia
Phone: +61 8 8347 3622
Fax: +61 8 8445 6328

Western Australia
Phone: +61 8 9240 5655
Fax: + 61 8 9240 5644

Wellington New Zealand
Phone: + 64 4 477 4717
Fax: +64 4 477 3691

Powerware and ABM are trade names,
trademarks and/or service marks of
Eaton Power Quality Corporation
or its subsidiaries and affiliates. All
other trademarks are property of their
respective owners.

* Up to 4 EBMs can be connected. EBM runtimes include internal batteries. This guide provides typical application information. Battery run times are approximate and
may vary with equipment, configuration, battery age, temperature, etc.

Battery Runtimes (in minutes full load/half load)*

Model

Standard Internal

Batteries

1 EBM

2 EBMs

3 EBMs

4 EBMs

1000VA

5/16

48/110

100/220

170/6h

4h/8h

1500VA

6/17

33/79

63/146

92/174

120/201

2000VA

6/15

30/70

60/190

90/215

120/240

2200VA

5/14

26/60

55/170

81/198

106/224

POWERWARE 5125

Rating

1000VA

1500VA

2000VA

2200VA

Part Number

51251000A

51251500A

51252000A

51252200A

Capacity (VA/Watts)

1000/700

1500/1050

2000/1400

2200/1600

Dimensions WxDxH (mm)

162x401x250

162x467x250

205x493x250

205x493x250

Weight (kg)

16

23

31

31

Input Connection

IEC320/10A

IEC320/10A

IEC320/10A

IEC320/16A

Output Connection

4 x AUST. 10A

4 x AUST. 10A

6 x AUST. 10A

6 x AUST.10A

Typical runtime (Full load)

5 min

6 min

6 min

5 min

Operational

Nominal input voltage (Vac)

220/230/240 Vac

Input voltage range

166-276 VAC (+15/-30% of nominal)

Operating frequency

50/60 Hz auto sensing

Input power factor

Same as load

Nominal output voltage

220/230/240 VAC

Output voltage regulation

-10%/+6% of selected nominal voltage

Overload capacity

110% 3 min; 150% 10 cycles

Efficiency

95%

User interface

LED Information

LED display

Standard communication ports

RS232

Optional

SNMP/WEB card, USB card, relay cards

Environmental

Operating temperature

0oC - +40oC

Storage temperature

-15oC - +55oC

Altitude

< 3000 m

Audible noise at 1 metre

< 45dB normal mode
< 50dB battery mode

Certification

Markings

CE/GS/UL/C-Tick

Safety

EN 50091-1-1 & UL 1778

EMC

EN 50091-2, EN6100-3-2

Advertising