DX810 –

13

Preset Active
A logic output can indicate when a particular preset
is active.
Force On
A logic output can indicate when a particular input
or group is being forced on.
Priority active
A logic output can indicate when a particular input
or group force-on priority is active.
Combine active
A logic output can indicate when a particular
combination (combine) is active.
Gate Status
A logic output can indicate when a particular Input
Gate is open.

Note: An input gate that is disabled (off) is

always open.

PASSWORD PROTECTION

There are two levels of password protection, User
and Administrator.

User Level

User level provides access to the front panel
controls and the fader controls in the DX-810-PC
application.The MODE button on the front panel is
used to disable the front panel controls by selecting
LOCK. The LOCK LED blinks for about five seconds
before it engages. When the LED lights steadily, the
front panel controls are disabled.

To unlock the DX810 from the front panel, press

the bottom “Down” buttons on the front panel in
the correct numerical sequence. Use the following
chart:

Input 1 Down = 1
Input 2 Down = 2
Input 3 Down = 3
Input 4 Down = 4
Input 5 Down = 5
Input 6 Down = 6
Input 7 Down = 7
Input 8 Down = 8
Low EQ Down = 9
Hi EQ Down = 0

Note: The default User Lock Code is “1234.”

The buttons must be pressed in rather rapid
sequence in order to unlock the front panel (no
more than about 1 second between key presses).

Administrator Level

Administrator Level provides access to all of the
DX-810-PC software application functions. When
you click the On Line button in the application to
begin communication between the application and
the DX810, the Enter Pass Code window opens.
Entering the four-digit User Pass Code limits you to
fader control only. Entering the four-digit
Administrator Pass Code (previously defined in the
Set Lock Code window under the Advanced menu)
allows you full access to the software controls.

Note: The default administrator code is “1234.”

5. DX-810-PC SOFTWARE (v 3.3)

INSTALLING THE SOFTWARE

A PC-based Windows-style graphical interface
software application is provided on a CD-ROM. This
is to control and configure the DX810 at the point of
installation.

Check our website at www.eawcommercial.com

for software upgrades as they become available.

To install the software on a PC:

It is necessary to install the DX-810-PC software

on your PC.

1. Make sure no other applications are running.

2. Insert the DX810 CD into your PC’s CD drive, or

download the software from
www.eawcommercial.com.

3. The CD should begin the installation automatically.

If not, click Start, then click Run.

4. Type <drive>:\DX-810-PC\Setup in the command

line (where <drive> is the letter assigned to the CD
drive, i.e., D drive, or the location on your hard
drive where the file was downloaded).

5. Setup will install the DX-810-PC application onto

your PC. You can accept the default directory, or
specify a different location to install the
application.

UPGRADING THE SOFTWARE

From time to time, EAW Commercial will release
upgrades for the internal operating software in the
DX810. This can be downloaded from our website
(www.eawcommercial.com) to a PC-compatible
computer. Use the serial port on the computer to
connect to the COMM PORT on the DX810. Then
transfer the data to the on-board flash memory with
the DX-810-PC software.