Extron AAP 100 and MAAP 100 Installation Guide

The following procedure is for mounting the AAP 100 and MAAP 100 panels

on hard surfaces (plywood, hardwood, etc.). For soft surfaces (particle

board, drywall, etc.), additional hardware such as anchors may be required

(not provided).

1.

Make a copy of the appropriate full size rough-in template. Cut out the

center portion of the template up to the dashed guidelines.

C

For accurate sizing, copy the template at exactly 100%.

2.

Place the template in the desired location and mark the guidelines for

the opening on the surface.

3.

Carefully cut away the material inside the guidelines. Check the

opening size by placing the panel against the opening.

4.

Cable the AAP(s)/MAAP(s) and install them on the panel.

5.

Place the panel against the surface and mark the locations of the two

wall mounting holes on the surface.

6.

Remove the panel and drill 1/4" deep pilot holes (half the width of the

shaft of the screw) at the marked locations. Replace the panel.

7.

Use two 1/2" (1.3 cm) long, #6 flat headed wood screws (provided) to

fasten the panel directly onto the surface. Hand tighten the screws.

Product Dimensions

68-837-01 Rev. B

08 08

AAP 100 pnl.eps

1.750

2 x 0.875

0.000

0.250

4.250

4.500

0.000

0.100

MAAP 100 pnl.eps

0.000

0.250

3.000

3.250

1.750

2 x 0.875

0.000

0.100

The dashed line indicates the

recommended cut-out area

for the installation surface.

1.5" H x 2.25" W

(3.8 cm H x 5.7 cm W)

The solid, outer line

represents the outside

edge of the panel.

1.75" H x 3.25" W

(4.45 cm H x 8.25 cm W)

The dashed line indicates the

recommended cut-out area

for the installation surface.

1.5" H x 3.5" W

(3.8 cm H x 8.9 cm W)

The solid, outer line

represents the outside

edge of the panel.

1.75" H x 4.5" W

(4.45 cm H x 11.4 cm W)

Template for

the AAP 100

Template for

the MAAP 100

Installation Templates

© 2008 Extron Electronics. All rights reserved.

Extron

USA - West

Headquarters

+800.633.9876

Inside USA / Canada Only

+1.714.491.1500

+1.714.491.1517 FAX

Extron

USA - East

+800.633.9876

Inside USA / Canada Only

+1.919.863.1794

+1.919.863.1797 FAX

Extron

Europe

+800.3987.6673

Inside Europe Only

+31.33.453.4040

+31.33.453.4050 FAX

Extron

Asia

+800.7339.8766

Inside Asia Only

+65.6383.4400

+65.6383.4664 FAX

Extron

Japan

+81.3.3511.7655

+81.3.3511.7656 FAX

Extron

China

+400.883.1568

Inside China Only

+86.21.3760.1568

+86.21.3760.1566 FAX

Extron

Dubai

+971.4.2991800

+971.4.2991880 FAX

The dashed line indicates the

recommended cut-out area

for the installation surface.

1.5" H x 2.25" W

(3.8 cm H x 5.7 cm W)

The solid, outer line

represents the outside

edge of the panel.

1.75" H x 3.25" W

(4.45 cm H x 8.25 cm W)

The dashed line indicates the

recommended cut-out area

for the installation surface.

1.5" H x 3.5" W

(3.8 cm H x 8.9 cm W)

The solid, outer line

represents the outside

edge of the panel.

1.75" H x 4.5" W

(4.45 cm H x 11.4 cm W)

Template for

the AAP 100

Template for

the MAAP 100

Advertising
This manual is related to the following products: