CHAPTER 2: S5U1C63000H2 PACKAGE

2.5 Setting the Dip Switch

The S5U1C63000H2 works with a personal computer that runs Windows as a host. With a general
computer that meets the condition, the serial transfer rate set at the factory (9600 bps) is good for use. In
case the rate is changed, the transfer rate between the host computer can be changed by this switch. The
switch also sets a self diagnostic function, which is equipped in the S5U1C63000H2, working or not
working at the power on. Figure 2.5.1 shows the dip switch.

— O P E N —

1

2

3

4

5

6

7

8

Fig. 2.5.1 Dip switch

<Setting baud rate>

SW1–3

OPEN

OPEN

OPEN

OPEN

OPEN

Other settings

SW4

OPEN

OPEN

ON

OPEN

ON

SW5

OPEN

ON

OPEN

OPEN

ON

SW6

OPEN

ON

ON

ON

OPEN

Baud rate setting

9600 bps, 8-bit character, 1 stop bit, no parity (factory setting)

2400 bps, 8-bit character, 1 stop bit, no parity

4800 bps, 8-bit character, 1 stop bit, no parity

19200 bps, 8-bit character, 1 stop bit, no parity

38400 bps, 8-bit character, 1 stop bit, no parity

Do not set.

Note: The setting at the host end is recommended to be "9600 bps, 8-bit character, 1 stop bit, no parity".

<Setting the self diagnostic function>

SW8

OPEN

ON

Setting

Self diagnosis On

Self diagnosis Off (factory setting)

Note: When the S5U1C63000H2 is started with the self diagnosis on, it takes approx. 5 minuets to be

ready for use.

Open means that the switch lever is at upper side.
On means that it is at lower side.