Kichler 2666 User Manual

Kichler Lighting

Advertising
background image

1)

Turn off power.

2)

Determine the height from ceiling that you would like your fixture to
hang. Fixture is provided with (3) 292mm (11 1/2”) long tubes that
can be used or omitted to achieve desired height.

3)

Assemble stem to fixture — First read and understand directions on
thread locking compound marked on illustration.
NOTE: Thread locking compound must be applied to all stem
threads as noted by symbol (

) to prevent accidental rotation of

fixture during cleaning, relamping, etc.

4)

Please note direction of exposed threaded pipe on illustration.
Bottom two pipes will have exposed thread at top. top pipe will not
have exposed threaded pipe.

5)

Take large diameter threaded pipe form parts bag and screw into
hangstraight a minimum of 1/4’. Lock into place with a hexnut.

6)

Run a hexnut down threaded pipe almost touching first hexnut. Now
screw threaded pipe into mounting strap. Mounting strap must be
positioned with extruded thread faced into outlet box. Threaded
pipe must protrude out the back of the mounting strap.

7)

To correctly position mounting strap and threaded pipe, put mount-
ing strap on flat surface and place canopy over top. Approximately
one-half of the hangstraight exterior thread should be exposed.
Tighten hexnuts against mounting strap and hangstraight.

8)

After the desired position is found, tighten the hexnut up against the
bottom of the mounting strap.

9)

Carefully slip lock ring, then canopy over assembled tubes on fix-
ture.

10) Thread assembled hangstraight and mounting strap into top tube on

stem assembly.

11) Attach assembled fixture to outlet box. (Screws not provided).
12) Connect ground wire from fixture and ground wire from outlet box in

outlet box

11) Make wire connections (connectors not provided). Reference chart

below for correct connections and wire accordingly.

12) Push canopy to ceiling and secure in place with lock ring.

Connect Black or

Red Supply Wire to:

Connect

White Supply Wire to:

Black

White

*Parallel cord (round & smooth)

*Parallel cord (square & ridged)

Clear, Brown, Gold or Black

without tracer

Clear, Brown, Gold or Black

with tracer

Insulated wire (other than green)

with copper conductor

Insulated wire (other than green)

with silver conductor

*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)

Neutral Wire

OUTLET BOX

MOUNTING STRAP

HEXNUT

THREADED PIPE

HANGSTRAIGHT

LOCK RING

THREADED PIPE

CANOPY

EXPOSED THREAD

TUBE

Date Issued: 1/15/93

IS-2666-CB

INSTRUCTIONS

For Assembling and Installing Fixtures in Canada