DAV101CM, DAS101CM • Installation and Operation

2-5

connect the power supply to a DAS101CM module’s 12 VDC

In port and loop the power through to the DAV101CM via the

DAS101CM’s 12 VDC Out port (see

page 2-6

).

N

Do not tin the stripped power supply leads before

installing the captive screw connector.

C

Correct polarity is important! The power wires must

be attached to the correct terminals or the module can

be damaged.

b

15-pin HD computer-video output (DAV101CM-1, -2, -5) —

Attach this connector to the display’s 15-pin HD input

connector.

c

BNC computer-video output (DAV101CM-3, -4, -6) — Attach

these five male BNC connectors to the display’s BNC input

connectors.

DAS101CM Series, and DAV-DAS interconnection

12VDC

0.1 A

12VDC

0.1 A

DAS101CM-1, -2, -5
Top View

DAS101CM-3, -4, -6
Top
View

DAS101CM-1, -2, -5 Rear View

DAS101CM-3, -4, -6 Rear View

1

2

3

1

2

3

a

12 VDC, 0.1 A In (power input) — Connect a 12VDC, 1 A power

supply to these two poles of the DAS’s 4-pole direct insertion

captive screw connector for power input.

C

Correct polarity is important! The power wires must

be attached to the correct terminals or the module can

be damaged.

b

12 VDC, 0.1 A Out (power loop-through for DAV101CM

modules)

— This port allows power to be looped through to a

DAV101CM. See the wiring diagram on the next page.