1. To reduce the risk of electric shock, insure

electricity has been turned off at the circuit

2.

3. WARNING: To reduce the risk of electrical

4.

5. The outlet box and support structure must

be securely mounted and capable of
reliably supporting a minimum of 50
pounds. Use the outlet boxes marked
"FOR FAN SUPPORT".

6. The fan must be mounted with a minimum

of 7 feet clearance from the trailing edge of
the blades to the floor.

7. To operate the reverse function on this fan,

press the reverse button while the fan is
running.

8. Avoid placing objects in the path of the

blades.

9. To avoid personal injury or damage to the

fan and other items, be cautious when
working around or cleaning the fan.

10. Do not use water or detergents when

cleaning the fan or fan blades. A dry dust
cloth or lightly dampened cloth will be
suitable for most cleaning.

11. After marking electrical connections,

spliced conductors should be turned
upward and pushed carefully up into outlet
box. The wires should be spread apart with

12. Electrical diagrams are for reference only.

Light kits that are not packed with the fan
must be marked suitable for use with the
model fan you are installing.Refer to the
Instructions packaged with the light kits and
switches for proper assembly.

NOTE: NOT SUITABLE FOR USE WITH SOLID-
STATE SPEED CONTROLS.

1. SAFETY RULES

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC

SHOCK OR PERSONAL INJURY, MOUNT FAN TO

OUTLET BOX MARKED "ACCEPTABLE FOR FAN

SUPPORT".

WARNING

1

All wiring must be in accordance with the
National Electrical Code, ANSI/NFPA70-1999
and local electrical codes. Electrical installa-
tion should be performed by a qualified
licensed electrician.

WARNING: To reduce the risk of fire,
electric shock, or personal injury, mount
this fan to outlet box marked "Acceptable
for Fan Support"
and use mounting
screws provided with the outlet box. Most
outlet boxes commonly used for the sup-
port of light fixtures are not acceptable for
fan support and may need to be replaced.
Due to the complexity of the installation of
this fan, a qualified licensed electrician is
strongly recommended.

conductor of a fan identified as grounded
condutor to be connected to a grounded
conductor of power supply, conductor of fan
identified as ungrounded conductor to be
connected to an ungrounded conductor of
power supply,conductor of fan identified for
equipment grounding to be connected to an
equipment-grounding conductor.

breaker or fuse box before cleaning and
maintenace, attempting Installation.

shock and fire, do not use this fan with
any solid-state fan speed control device.

TO REDUCE THE RISK OF PERSONAL INJURY,
DO NOT BEND THE BLADE BRACKETS WHEN
INSTALLING THE BRACKETS, BALANCING THE
BLADES, OR CLEANING THE FAN. DO NOT
INSERT FOREIGN OBJECTS IN BETWEEN ROTAT-
ING FAN BLADES.