3-4

L14STA

Instructions for Handling
Semiconductors

Electrostatic breakdown of the semiconductors may
occur due to a potential difference caused by electro-
static charge during unpacking or repair work.

1. Ground for Human Body

Be sure to wear a grounding band (1M

Ω) that is prop-

erly grounded to remove any static electricity that may
be charged on the body.

2. Ground for Workbench

Be sure to place a conductive sheet or copper plate
with proper grounding (1M

Ω) on the workbench or

other surface, where the semiconductors are to be
placed. Because the static electricity charge on cloth-
ing will not escape through the body grounding band,
be careful to avoid contacting semiconductors with
your clothing.

CBA

<Incorrect>

Grounding Band

Conductive Sheet or
Copper Plate

1M

1M

<Correct>

CBA

Advertising