Elkay HRC4-191B User Manual

Installation instructions

Advertising
background image

97559C (REV. B - 1/00)

HRC4-191B HRC4-19-2B

NOTE:

It is important to insure proper ventilation. Allow a

minimum clearance of 12 inches (305 mm) in front and 3 inches

(76mm) in the rear of the unit. If unit is to be installed in an

enclosure, allow the following clearances around unit - 1 inch

(25mm) each side, 3 inches (76mm) in the rear, 3 inches

(76mm) inches above wall.

This chiller has been designed for use with potable water and

includes an o-ring seal on the drain plug. The fitting should

be replaced if the unit is to be used with more aggressive

fluids.

For use with photo processing applications, adjust

cold control to warmer settings.

HRC419 HRC41950

Refrigeration Packages

Installation Instructions

A = 3/8" O.D. TUBE WATER OUT

B = 3/8" O.D. TUBE WATER INLET

C = 3/8" O.D. TUBE TANK DRAIN

LEGEND

Advertising