Romii/romiii, Product specifications, Flow rate – Everpure ROM III User Manual

Page 2: Minimum temperature, Minimum pressure, Maximum pressure, Nominal production rate, Everpure warranty, Features

Advertising
background image

product specifications

This system has been tested by Everpure for the reduction of the substances listed below.

Influent Challenge Max. Permissible Product

Reduction

Minimum

Average

Substance

Concentration

Water Concentration

Requirements

Reduction

Reduction

%

0

.

8

9

%

6

.

6

9

L

/

g

m

5

2

0

.

0

%

0

1

±

L

/

g

m

0

3

.

0

ci

n

e

s

r

A

%

0

.

0

9

%

0

.

0

9

L

/

g

m

0

.

2

%

0

1

±

L

/

g

m

0

.

0

1

m

ui

r

a

B

%

4

.

6

9

%

0

.

0

9

L

/

g

m

5

0

0

.

0

%

0

1

±

L

/

g

m

3

0

.

0

m

ui

m

d

a

C

%

6

.

6

8

%

6

.

6

8

L

/

g

m

1

.

0

%

0

1

±

L

/

g

m

3

.

0

)t

n

el

a

v

a

x

e

H

(

m

ui

m

o

r

h

C

%

7

.

5

8

%

7

.

5

8

L

/

g

m

1

.

0

%

0

1

±

L

/

g

m

3

.

0

)t

n

el

a

vi

r

T

(

m

ui

m

o

r

h

C

%

2

.

9

9

%

5

.

6

9

L

/

g

m

3

.

1

%

0

1

±

L

/

g

m

0

.

3

r

e

p

p

o

C

%

2

.

5

9

%

9

.

9

8

L

/

g

m

5

.

1

%

0

1

±

L

/

g

m

0

.

8

e

di

r

o

ul

F

%

1

.

8

9

%

7

9

L

/

g

m

0

1

0

.

0

%

0

1

±

L

/

g

m

5

1

.

0

d

a

e

L
Nitrate plus Nitrite (both as N)

30.0 mg/L ± 10%

10.0 mg/L

%

4

.

0

8

%

3

.

4

7

L

/

g

m

0

.

0

1

%

0

1

±

L

/

g

m

0

.

7

2

)

N

s

a

(

e

t

a

rti

N

%

8

.

5

7

%

3

.

8

6

L

/

g

m

0

.

1

%

0

1

±

L

/

g

m

0

.

3

)

N

s

a

(

e

tir

ti

N

%

8

.

6

9

%

0

.

3

9

L

/

g

m

5

0

.

0

%

0

1

±

L

/

g

m

0

1

.

0

m

ui

n

el

e

S

%

0

.

0

8

%

0

.

0

8

L

/i

C

/

p

5

%

0

1

±

L

/i

C

p

5

2

8

2

2

/

6

2

2

m

ui

d

a

R

%

6

.

4

9

%

4

.

2

9

L

/

g

m

7

8

1

L

/

g

u

0

4

±

L

/

g

m

0

5

7

s

di

lo

S

d

e

vl

o

s

si

D

la

t

o

T

%

9

9

.

9

9

%

9

9

.

9

9

%

5

9

.

9

9

L

/

0

0

0

,

0

5

m

u

m

in

i

M

ts

y

C

%

1

.

2

9

%

8

.

7

7

L

/

g

m

5

0

0

.

0

%

0

2

±

L

/

g

m

5

1

0

.

0

*

E

B

T

M

%

0

.

9

9

%

0

.

5

9

L

/

g

m

5

1

.

0

L

/

g

m

0

3

.

0

m

r

o

f

o

r

ol

h

C

Actual system performance may vary depending on water pressure, water temperature and other substances which may be found in water.

%

0

.

9

9

%

0

.

6

9

10 ppb

265 ppb

VOCs*

Everpure, Micro-Pure and the silver canister color are registered trademarks of Everpure, LLC © 2008

®

®

ROMII/ROMIII

Commercial grade reverse osmosis systems

for the home

This drinking water system must be

maintained according to the

manufacturer's instructions, including

replacement of filter cartridges. The

substances reduced or removed by this

system are not necessarily in your water.

Read the performance data sheet.

flow rate

Controlled at 0.5 gal./min. (1.9 L/min.)

minimum temperature

40-100° F (2-38° C) cold water use only

minimum pressure

40 psig. (280 kPa)

maximum pressure

125 psig. (860 kPa)

nominal production rate*

14.4 gal/day (54 Lpd)

* this may vary depending on specific water conditions

everpure warranty

Everpure Drinking Water Systems are

warranted to be free of defects for a full

twelve (12) months after purchase. A

detailed warranty statement is provided

with each system.

ROM II Reverse Osmosis Drinking Water System ( EV9273-85)
ROM III Reverse Osmosis Drinking Water System (EV9273-86)
S-101 Prefilter Cartridge “A” (EV9273-77)
TFC RO Cartridge “B” (EV9273-70)
ROM III VOC #1 Cartridge “C” (EV9273-79)

Features:

> Finely polishes treated water to premium quality for drinking and cooking.
> Reduces chlorine taste and odor.
> Reduces dirt, rust, asbestos fibers, and other particulates such as oxidized iron, manganese, and

sulfides.

> Reduces parasitic protozoan cysts such as Giardia, Entamoeba, and Cryptosporidium.
> Controls even extreme levels of common “off” tastes and odors, including those which are earthy,

moldy, and fishy.

> Reduces lead to below the Federal Action Level.
> Effectively reduces Volatile Organic Chemicals (VOCs), including Trihalomethanes (THMs).
> Effectively reduces methyl tertiary-butyl ether (MTBE).
> Inhibits limescale build-up in water-using applications.

General Installation/Operation/Maintenance Requirements:

> It is recommended that before purchasing a water treatment unit, you have your water tested to

determine your actual treatment needs.

> Space required: 12” wide x 17” high x 4” deep (30 x 43 x 10 cm), plus an additional 3 inches of

clear space under unit for cartridge change.

> Install vertically with cartridges hanging down.
> Use minimum length of tubing possible.
> Flush all cartridges,“A”, “B” and “C” per Installation and Use Manual provided with unit.
> S-101 Prefilter Cartridge “A” and VOC #1 Organics Cartridge “C” should be changed every 6

months. Properly maintained, TFC RO Cartridge “B” will last 2-3 years under average water
conditions. It is not possible to be specific about gallonage limits because turbidity and other aspects
of water quality are unpredictable.

> A separate drinking water faucet is required.