Performance data, Features, Health claim performance certified by nsf/ansi – Everpure CB20-312E User Manual

Page 2: Operating specifications, Special notices

Advertising
background image

PERFORMANCE DATA

CB20-312E System Replacement Cartridge Kit EV9105-34
1- CC1E Replacement Cartridge (Gray end caps)
2- CC3E Replacement Cartridge (White end caps)

FEATURES

Finely polishes treated water to premium quality for drinking and
cooking.

Reduces disinfectant chlorine taste & odor and chloramine taste &
odor.

Reduces dirt, rust, and other particulates such as oxidized iron,
manganese, and sulfides.

Reduces parasitic protozoan cysts such as Giardia, Entamoeba,
Cryptosporidium.

Reduces common earthy, moldy, fishy tastes and odors.

HEALTH CLAIM PERFORMANCE CERTIFIED
BY NSF/ANSI*

This system has been tested according to NSF/ANSI 42 and 53 for
the reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to a
concentration less than or equal to the permissible limit for water leav-
ing the system, as specified in NSF/ANSI 42 and 53.

Substance

Influent Challenge

Max. Permissible Product

Reduction

Minimum

Average

Concentration

Water Concentration

Requirements Reduction Reduction

Aesthetic Effects

Chlorine

2.0 mg/L ± 10%

≥50%

97.5%

Chloramine

3.0 mg/L ± 10%

0.5 mg/L

97.5%

Particulate, Class I
particles

at least 10,000

≥85%

99.1%

0.5 to < 1µm

particles/mL

Health Effects

Cyst†

Minimum 50,000/L

99.95%

99.99%

99.99%

Turbidity

11 ± 1 NTU

0.5 NTU

98.9%

99.2%

† Based on the use of microspheres.

* Tested using Flow rate = 5.0 gpm; Pressure = 60 psig; pH = 7.5 ±0.5; Temperature = 20˚C ±3˚C

OPERATING SPECIFICATIONS

Capacity: 60,000 gallons (227,100 L)
Pressure requirement: 20 - 100 psi (1.4 - 6.9 bar), non-shock
Temperature: 35 - 100°F (2-38°C)
Flow Rate: 5 gpm (19 Lpm)
Operating Weight: 90 lbs.

GENERAL INSTALLATION/OPERATION/
MAINTENANCE REQUIREMENTS

Mount system to wall studs 16" on center (spacing of mounting
plate holes) on other surface capable of supporting 90 pounds
when system is filled with water.

Connect water supply to inlet of CB20-312E system.

Connect outlet water to beverage equipment.

After installing the CC1E cartridge, flush cartridge at full flow for 5
minutes. Install CC3E cartridges and flush system for
10 minutes.

Replace cartridges when capacity is reached, or when flow
becomes too slow, but at least every 6 months.

SPECIAL NOTICES

Installation instructions, parts and service availability, and
standard warranty are included with the product when shipped.
Installation by certified installer is recommended.

This drinking water system must be maintained according to man-
ufacturer’s instructions, including replacement of filter
cartridges.

Do not use with water that is microbiologically unsafe, or of
unknown quality without adequate disinfection before or after the
system. Systems certified for cyst reduction may be used on dis-
infected waters that may contain filterable cysts.

The contaminants or other substances removed or reduced by
this water treatment system are not necessarily in your water.

Check for compliance with state and local laws and
regulations.

Testing was performed under standard laboratory conditions;
actual performance may vary.

©2005 by Everpure, LLC

MR/05 146527 Rev A

EVERPURE, LLC
1040 Muirfield Drive
Hanover Park, IL 60133

TEL 800-323-7873

Customer Service
FAX 800-942-0081

Visit us online at: www.everpure.com

In Europe:
EVERPURE EUROPE NV
Toekomstlaan 30
B-2200 Herentals
Belgium
Tel 32 14 28 35 00
FAX 32 14 28 35 05

In Japan:
EVERPURE JAPAN, INC.
1-8-19, Tsumada Kita,
Atsugi-Shi
Kanagawa 243
Japan
Tel 81-462 (23) 6563
FAX 81-462 (21) 6775

Advertising