Connection to an automobile battery

• Loosen the red screw on the power inverter as

much as is needed for you to be able to place
the red cable shoe of the red cable with the
connection terminal

with the opening under

the screw and washer.

• Turn the red screw so tight that the cable shoe

can no longer become unattached.

• Loosen the black screw on the power inverter as

much as is needed for you to be able to place
the black cable shoe of the black cable with the
connection terminal

with the opening under

the screw and washer.

• Turn the black screw so tight that the cable shoe

can no longer become unattached.

• First connect the red terminal clamp to the plus

pole of the automobile battery and then the
black terminal clamp to the minus pole of the
battery.

Connection and operation of a

load/device

Attention!

Before connecting a load/device to the power in-
verter make sure that the on/off switch

e

on

the device is in the position 0.
Make sure that the power of the load/device
does not exceed the maximum continuous load of
the power inverter.

• Insert the plug of the connecting load/the device

to be operated into the 220 - 240 V socket

r

of the power inverter.

Attention!

Do not switch on the load/device to be
operated yet!

B

B

• Switch the power inverter on by moving the on/off

switch

e

to the position I. If the power inverter

is functioning properly the operation LED/Over-
load indicator

w

will light up green.

• Now switch on the load/device to be operated.

When switched on a short signal tone can be
heard.

Note:

If a signal tone can be heard and the operation
LED/ Overload indicator

w

lights up red the

input voltage is too low or the power of the
load/device connected to the power inverter
is too high.

Device operation information

General notes

Usually on the device's rating plate you can find
information regarding the power consumption in
amperes (A) or the wattage (W).
Before operation make sure that the maximum power
consumption does not exceed 1,3 A and the maxi-
mum continuous load is not more than 300 W.
• Loads with a high internal resistance operate

very well with the power inverter, on the other
hand, loads with a low internal resistance, for
example heating and cooking devices have a
power consumption in watts that is too high.

IB_71660_TSW300A1_GB_LB5.qxd 21.11.2011 16:11 Uhr Seite 36