Risk of fire!

• Do not use the device near hot surfaces.
• Do not locate the device in places exposed to

direct sunlight, Otherwise, it may overheat and
become irreparably damaged. Do not operate
the device in a vehicle that is standing out in the sun.

• Do not leave the device unattended when in use.
• Do not cover the fan's ventilation slots when the

device is switched on.

• Do not place any open sources of fire, like candles,

on the device.

• Due to high crossover resistances heating of the

plug in connector can result when using the ca-
bles with a 12 V vehicle plug.

Notice regarding disconnection from
the power supply

• This device's on/off switch does not completely

disconnect the device from the vehicle's power
and/or the battery. When the vehicle plug is
connected power is still supplied to the device.
To completely disconnect the device from the
vehicle power supply the 12 V vehicle plug must
be removed from the 12 V vehicle receptacle.

Risk of personal injury!

• Keep children away from the connecting cable

and the device. Children frequently underestimate
the dangers of electrical appliances.

• Do not operate the device if it has fallen or is

damaged. Have the device checked and repaired
if necessary by qualified technicians.

Technical data

DC Input

Voltage :

12V

Maximum voltage:

15,5 V

Maximum power
consumption:

20 A

Underload alarm:

at 10,6 ± 0,3 V

Underload shutoff:

at 10 ± 0,3 V

Overload shutoff:

at 16 ± 0,5 V

AC Output

Voltage :

220-240 V ~ 50 Hz

Output power:

0,65 A

Continuous load:

150 W (> 4 h)/
170 W (30 min)

Peak load:

300 W (0,1 s)

Efficiency:

approx. 85 %

Output wave form:

modified sine

Overload protection:

200 W (+/- 5%)

Temperature Switch-off: 65°C

(at 50W +/- 5% Loading)

Fuses

Power inverter:

20 A automotive flat fuse

Power failure protection switch

Power failure
shut off:

>3 mA

General data

Measurements (without vehicle plug)
(L x B x H):

185 x 73 x 58 mm

Weight :

470 g approx.

Operating temperature:

5°...40°C

Operational humidity:

0 - 80 %

(relative humidity - no condensation)

Subject to technical changes.

IB_KH3901_BK42307_EN_LB6.qxd 12.12.2008 11:44 Uhr Seite 3

Advertising