3

1

5

6

11

12

C

A

B

locking ring

handle

The Style FX are adapted for operation on 190-260V/50-60Hz.

Before connecting for the first time, check to make sure that your modelling lamp coincides

with the voltage line.

They must always be connected to an earthed ( grounded) mains supply.

All Style FX units have a bayonet mount and locking ring reflector fitting, for fixing all Elinchrom and

Prolinca accessories.

Mount the unit securely to a suitable stand or support.

Remove the black protective cover (note: first turn the locking ring A as shown, then rotate the

black cap cover B in the same direction). Fitting a reflector or accessory is the reverse of this action.

DO NOT operate the unit without first removing the black protective cover.

1.Check that the modelling lamp voltage is correct.

2.Check that the mains switch (3) is in the OFF ("O" position).

3.Insert mains cable to the MAINS INLET (1) and connect to a FULLY EARTHED OUTLET

4.Connect the synchro cord to the socket (6).

5.Using the mains SWITCH (3) and switch the unit ON ("I" position).

6.Select the power with the touch pad (11 - 12)

Operating instructions