instructions for:

non-contact voltage detector

MoDEL no:

aK1998.v2

thank you for purchasing a sealey product. Manufactured to a high standard this product will, if used according to these instructions and

properly maintained, give you years of trouble free performance.

IMPORTANT: PleaSe read tHeSe InStrUctIonS careFUllY. note tHe SaFe oPeratIonal reQUIreMentS, WarnIngS, and

caUtIonS. USe tHIS ProdUct correctlY, and WItH care For tHe PUrPoSe For WHIcH It IS Intended. FaIlUre to do So

MaY caUSe daMage, or PerSonal InJUrY, and WIll InvalIdate tHe WarrantY.

1. SaFetY InStrUctIonS

2. IntrodUctIon

3. SPecIFIcatIon

fig.3

Original Language Version

Specifications:

Dimensions: 26mm Diameter (approx.) x 160mm.

Display: Green & red LED,s.

Power supply: 2 x AAA Batteries.

static current: not more than 5mA.

Dynamic current: not more than 35mA.

Power-off current: not more than 5uA

recommended use: indoor.

operating Voltage range: 80-1000vac.

High Voltage range: 220V and above.

Low Voltage range: 80V

frequency range: 50/60Hz.

over-voltage category: cAtiii, 1000V.

insulationProtection Level: iP40.

output:flashing: LED + Audio signal.

operating Ambient temperature: 0° to 40°c @ rH<95%.

storage temperature: -20°c to 40°c

Working Ambient Humidity: <95%.

Altitude: <2000m.

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPortant: no liability is accepted for incorrect use of this product.

WarrantY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

InForMatIon: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500
01284 703534

[email protected]

Sole UK distributor, Sealey group,

Kempson Way, suffolk Business Park

,

Bury st. Edmunds, suffolk,

iP32 7Ar

www.sealey.co.uk

Web

email

1.1.

When using the detector refer to the following:

1.1.1. for use only within the operating range specified in section 3.

1.1.2

do not expose the unit to extreme temperature or high humidity.

refer section 3. recommended for use indoors.

1.1.3. Before use confirm that the detector casing is undamaged,

do not use

if any fault is found or if wet.

1.1.4. Before use check the operation of the detector by "testing" a known live

cable

1.1.5.

do not use the detector for any purpose other than for which it is

designed.

1.1.6. Always have detected faults to be rectified by a qualified electrician.

1.1.7. After rectification check the detector as in 1.1.4. iMPortAnt

1.1.8.

do not rectify any fault until the supply fuse/circuit breaker has

been removed/opened.

the AK1998.V2 is designed for testing insulated conductors for the presence of

Ac voltages. no electrical connection to the conductor under test; live, neutral

or earth, is required. Maintenance free powered by two 1.5V batteries.

environmental Protection.

recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted,

taken to a recycle centre and disposed of in a manner which is compatible with the environment.

When the product is no longer required, it must be disposed of in an environmentally protective way. contact your local solid

waste authority for recycling information.

onlY dispose of batteries or recycle according to local authority regulations. under the Waste Batteries and Accumulators

regulations 2009, Jack sealey Ltd. are required to inform potential purchasers of products containing batteries (as defined within

these regulations), that they are registered with Valpak's registered compliance scheme. Jack sealey Ltd's Batteries Producer

registration number (BPrn) is BPrn00705.

© Jack sealey Limited

AK1998.V2 issue: 1 - 09/08/12

fig.2

IMPortant! the aK1998.v2 will not detect voltages in cables

connected to a centre tapped earth supply e.g. 110v transformer

or generator.

4. oPeratIon

4.1

With the batteries installed (see section 5), turn the unit on by rotating

the switch to choose high or voltage sensitivity. the green LED will flash

once and the audible output beep once when "High V" or "Low V" is

selected. this indicates the batteries are functioning correctly.

4.2

Bring the probe (fig.1) in close proximity to the conductor, the red LED

and audio output will indicate the presence of an Ac supply voltage

within the range stated in the specifications. to determine magnitude

and or frequency an appropriate metering device is required.

4.3 insulated cores may be checked for continuity breaks (fig.3).

nb! each core must be individually connected to a detectable voltage.

4.4 Electrical sockets (80V - 220V) can be checked by placing the

probe tip into socket terminal aperture.

note!: Wait until the LED and the audible output finishes before

proceeding with the next operation.

using this device near equipment that generates electromagnetic

interference may result in inaccurate indications.

5. BatterIeS

5.1

for removal use a small screwdriver to lift probe casing cap.

5.2 install batteries with polarity as shown in fig.2 and replace cap,

pressing it home until it latches.

5.3 for disposal see notes below (Environmental Protection).

fig.1

6. cleanIng

6.1 Periodically wipe the casing with a damp cloth and mild detergent.

do not use abrasives or solvents.