Warning – Emerson CF945PW User Manual

Page 7

Advertising
background image

7

If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.

10. Connect the green grounding lead from the hanger

ball and the green grounding lead from the hanger
bracket to the grounding conductor of supply (this
may be a bare wire or wire with green colored
insulation). Securely connect wires with wire
connector supplied. (Figure 10).

11. Securely connect the fan motor white wire to the

supply white (neutral) wire using wire connector
supplied (Figure 10). Securely connect the fan
motor black wire to the supply black (hot) wire
using wire connector supplied (Figure 10). After
connections have been made, turn leads upward
and carefully push leads into the outlet box.

To avoid possible electrical shock, be sure electricity
is turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is ground-
ed, contact a licensed electrician for advice, as it
must be grounded for safe operation.

WARNING

!

OUTLET
BOX

HANGER
BRACKET

HANGER BALL/
DOWNROD ASSEMBLY

NOTE: CEILING COVER,
SUPPLY WIRES AND
FAN WIRES OMITTED
FOR CLARITY.

Figure 9

THREADED
STUD (2)

HANGER
BRACKET

WHITE SUPPLY
(NEUTRAL)

GREEN WIRE
(GROUND) FROM
HANGER BRACKET

LISTED WIRE
CONNECTOR (3)

SUPPLY
GROUND WIRE

GREEN WIRE
(GROUND) FROM
HANGERBALL

BLACK FAN
WIRE

BLACK SUPPLY
(HOT)

WHITE
FAN WIRE

Figure 10

Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.

WARNING

!

12. Screw the two threaded studs (supplied) into the

tapped holes in the hanger bracket (Figure 10).

13. Lift the ceiling cover up to the threaded studs and

turn until studs protrude through the holes in the
ceiling cover (Figure 11).

14. Secure the ceiling cover in place by sliding lockwash-

ers over the threaded studs and installing the two
knurled knobs (supplied) (Figure 11). Tighten the
knurled knobs securely until the ceiling cover fits
snugly against the ceiling.

CEILING COVER

THREADED STUD

KNURLED KNOB

LOCKWASHERS (2)

Figure 11

To avoid possible fire or shock, make sure that the
electrical wires are completely inside the outlet box
and not pinched between the ceiling cover and the
ceiling.

WARNING

!

15. Mount blade flanges to fan blades using three

3/16-24 x 3/8” slotted washer head blade screws,
three plastic washers (Figure 12).

NOTE: Take care not to scratch fan housing when
installing blades.

NOTE: Remove and discard the four shipping
spacers and screws from the motor hub.

3/16-24 X 3/8" WASHER
HEAD BLADE SCREW (3)

PLASTIC WASHER (3)

FAN BLADE

BLADE
FLANGE

Figure 12