EverFocus EQ150 User Manual

Page 8

Advertising
background image

1. Focal Length Adjustment Ring

Use this ring to adjust the appropriate focal length according to the type of

lens. Rotate the ring clockwise for the CS-mount lens, rotate it

counterclockwise for the C-mount lens. The factory setting is C-mount.

2. Lens Mount

To mount an appropriate C-mount or CS-mount lens.

3. Locking Screw

Use the locking screw to fix the focal length.

4. Lens Connector (4 pin socket)

To connect to the lens plug of the auto iris lens.

5. Control Switches

There are 6 control switches located on the sideboard, which are for the

setting of the special features. The switches in orders are for Flickerless,

Back Light Compensation, Electronic Shutter, Automatic Gain Control,

Line-Lock and Auto Iris Lens type.

FL (Flickerless Function) On/Normal

When picture flicker fiercely, turn FL on, then the camera will stabilize the

speed of electronic shutter at 1/100(EIA) or 1/120(CCIR) automatically, and

reduce the flicker immediately. The default setting is Normal.

BLC (Back Light Compensation) On/Normal

When BLC is turned on, the AGC, ES and IR IS operating point is

determined by averaging over the center area instead of entire field-of-view,

so that a dimly-lit foreground object at center area can be clearly

distinguished from brightly-lit backgrounds.

BLC should not be used unless it is needed to compensate for back-lit. The

default setting is Normal.

5

Advertising