Sealey VSE953 User Manual

Sealey Tools

Advertising
background image

INSTRUCTIONS FOR:

CATALYTIC CONVERTER BACK PRESSURE

TEST KIT

MODEL No:

VSE953

3. OPERATION

2. INTRODUCTION AND SPECIFICATION

IMPORTANT:

Always refer to the vehicle manufacturer’s service instructions, or proprietary manual to establish the current procedure and

data.These instructions are provided as a guide only.

Ensure all Health and Safety, local authority, and general workshop practice regulations are strictly adhered to when using product.

Maintain

tools in good and clean condition for best and safest performance. DO NOT use test kit if damaged.

Account for all tools and parts being used and do not leave them in, or on the engine after use.

Ensure you have read and understood the safety aspects of dealing with the fuel injection system and petrol in general before commencing.

Personal / Operation

Wear approved eye protection. A full range of personal safety equipment is available from your Sealey dealer.

Keep yourself, clothing and test equipment away from all moving or hot engine parts.

Do not wear jewellery and tie back long hair.

Before performing a test with the engine running (unless the manufacturer's manual states otherwise), set the parking brake and place the

gear selector in neutral or park, and block the drive wheels.

Exhaust gas contains deadly poisonous gases. The test area must be well ventilated - route the exhaust gas outdoors.

Used to establish the working condition of the catalytic converter and silencer by measuring the relative back pressure of the system. Simply

connect into the exhaust system using either of the two oxygen sensor dummy adaptors supplied in the kit. Gauge features a colour coded scale

for easy diagnosis and reads both pressure and vacuum so can be used on other areas of the vehicle allowing testing of low pressure fuel systems

or engine vacuum. Supplied with gauge hanging chain to allow hands free operation.

Model No: . . . . . . . . . . . . . . . . . . VSE953

Contents: . . . . . . . . . . . . . . . . . . Oxygen Sensor Adaptors M12x1.25, M18x1.5

Small & Large Brass Cone Adapters

Plastic Double Ended Cone

Plastic 'T' Piece

Gauge Hanging Chain

Gauge Scale: . . . . . . . . . . . . . . . Pressure 0-10psi

Vacuum 0-60cmHg

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions

and properly maintained, give you years of trouble free performance.

IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS.

USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE

AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

Original Language Version

© Jack Sealey Limited

VSE953 Issue 1 - 19/06/13

3.1.

TESTING THROUGH THE OXYGEN SENSOR PORT

Note:

See section 4 for part numbers and description of each item.

WARNING! Exhaust systems can get very hot and testing should be carried out when the engine is cold to avoid injury (burns) and

so the rubber hose on the tool does not get too hot and distort. Testing should be completed within 5 minutes of the engine being

started from cold. Allow the engine to cool before removing the Oxygen sensor adaptors because these will be very hot and could

cause injury.

Note: Before replacing any suspected blocked exhaust components ALWAYS refer to the vehicle manufacturer's specifications to

obtain the correct pressure limits.

Note: Disconnecting the Oxygen sensor or running the engine with the sensor disconnected may cause the vehicle to illuminate

the MIL (Malfunction Indicator Light) which will require an EOBD diagnostic tool to reset it.

3.1.1.

If there are two or more oxygen sensors, start testing at the one nearest the engine and proceed 'downstream'. Disconnect the oxygen

sensor wires and remove the oxygen sensor.

3.1.2. Install the oxygen sensor adaptor (refer to section 4).

3.1.3. Connect the rubber hose and gauge (see fig.1) onto the oxygen sensor adaptor.

3.1.4. Start the engine and allow it to idle, the reading should not register over 1psi in the Green scale. If the gauge registers over this pressure,

stop the engine, locate the restriction and correct the fault (see 3.2).

3.1.5. If the idle reading is NOT above 1psi, rev the engine to 2500rpm. The reading should not register over 2.5psi, if the gauge registers over this

pressure, stop the engine, locate the restriction and correct the fault (see 3.2)

3.1.6. If the vehicle has more than one exhaust pipe, with two catalytic converters, each will need to be checked.

3.2.

TESTING THE CATALYTIC CONVERTER

3.2.1. If a blocked catalytic converter is suspected, test again after the converter using the second oxygen sensor (post cat) port. If the

converter is blocked the gauge will read a lower pressure than the first sensor (pre cat) port. For example, if the first oxygen sensor port

reads 4psi and the second oxygen sensor reads 0.5psi, this shows a blocked catalytic converter.

3.3.

TESTING VEHICLES WITHOUT OXYGEN SENSORS

3.3.1. If the vehicle isn't fitted with oxygen sensors or they can't be removed it is possible to drill a small hole in the side of the exhaust pipe, (away

from any welds and

NOT into the catalyst), and use one of the brass cone adaptors (see section 4.6 and 4.7) to obtain a reading. After

testing the small hole will require filling with either a small self tapping screw or weld.

Advertising