InstructIons for:

EXHAUST FUME EXTRACTOR

WITH 6mtr HOSE

Model no:

EFS/93.V4

thank you for purchasing a sealey product. Manufactured to a high standard this product will, if used according to these instructions

and properly maintained, give you years of trouble free performance.

IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS.

USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE

AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

1.2

GENERAL SAFETY

WARNING! Ensure Health & Safety, local authority, and

general workshop practice regulations are adhered to when

using this equipment.

familiarise yourself with the application, limitations and

potential hazards of the extractor.

WARNING! Disconnect the unit from the mains power

before servicing or performing any maintenance.

Maintain the extractor in good condition (use an authorised

service agent).

replace or repair damaged parts. Use genuine parts only.

Unauthorised parts may be dangerous and will invalidate the

warranty.

locate the extractor in a suitable working area, keep area clean

and tidy and free from unrelated materials. ensure there is

adequate lighting.

WARNING! Use only on level ground or slopes not exceeding 8º .

ensure there are no flammable or combustible materials near

the work area.

Keep children and unauthorised persons away from the working area.

DO NOT use the extractor for a task it was not designed to

perform.

DO NOT operate the extractor if any parts are damaged or

missing as this may cause failure or possible personal injury.

DO NOT get the extractor wet or use in damp or wet locations

or areas where there is condensation.

DO NOT allow untrained persons to operate the extractor.

DO NOT operate the extractor when you are tired or under the

influence of alcohol, drugs or intoxicating medication.

DO NOT use the extractor where there are flammable liquids,

solids or gases such as paint solvents, etc.

DO NOT leave the extractor operating unattended.

When not in use switch the extractor off and remove plug

from the power supply.

1.1. ELECTRICAL SAFETY

WARNING! It is the responsibility of the owner and the operator

to read, understand and comply with the following:

You must check all electrical products, before use, to ensure that they

are safe. You must inspect power cables, plugs, sockets and any

other connectors for wear or damage. You must ensure that the risk

of electric shock is minimised by the installation of appropriate safety

devices. A residual current circuit Breaker (rccB) should be

incorporated in the main distribution board. We also recommend that

a residual current device (rcd) is used. It is particularly important

to use an rcd with portable products that are plugged into a supply

which is not protected by an rccB. If in any doubt consult a

qualified electrician. You may obtain a residual current device by

contacting your sealey dealer. You must also read and understand

the following instructions concerning electrical safety.

1.1.1. the

Electricity at Work Act 1989 requires that all portable

electrical appliances, if used on business premises, are tested

by a qualified electrician, using a Portable Appliance tester

(PAt), at least once a year.

1.1.2. the

Health & Safety at Work Act 1974 makes owners of

electrical appliances responsible for the safe condition of

those appliances and the safety of the appliance operators. If

in any doubt about electrical safety, contact a qualified

electrician.

1.1.3. ensure that the insulation on all cables and on the appliance

is safe before connecting it to the power supply. see 1.1.1.

and 1.1.2. and use a Portable Appliance tester.

1.1.4. ensure that cables are always protected against short circuit

and overload.

1.1.5. regularly inspect power supply cables and plugs for wear or

damage and check all connections to ensure that none is loose.

1.1.6.

Important: ensure that the voltage marked on the appliance

matches the power supply to be used and that the plug is

fitted with the correct fuse - see fuse rating at right.

1.1.7.

DO NOT pull or carry the appliance by the power cable.

1.1.8.

DO NOT pull the plug from the socket by the cable.

1.1.9.

DO NOT use worn or damaged cables, plugs or connectors.

Immediately have any faulty item repaired or replaced by a

qualified electrician. When a Bs 1363/A uK 3 pin plug is

damaged, cut the cable just above the plug and

dispose of

the plug safely.

fit a new plug according to the following instructions (uK only).

a) Connect the GREEN/YELLOW earth wire to the earth

terminal ‘E’.

b) Connect the BROWN live wire to the live terminal ‘L’.

c) Connect the BLUE neutral wire to the neutral terminal ‘N’.

d) After wiring, check that there are no bare wires, that all

wires have been correctly connected, that the cable outer

insulation extends beyond the cable restraint and that the

restraint is tight.

double insulated

products, which are

always marked with this

symbol , are fitted

with live (brown) and

neutral (blue) wires only.

to rewire, connect the

wires as indicated to the

right.

DO NOT connect

either wire to the earth

terminal.

1.1.10. Products which require more than 13 amps are supplied

without a plug. In this case you must contact a qualified

electrician to ensure that a suitably rated supply is available.

We recommend that you discuss the installation of an

industrial round pin plug and socket with your electrician.

1.1.11. If an extension reel is used it should be fully unwound before

connection. A reel with an rcd fitted is preferred since any

appliance plugged into it will be protected. the cable core

section is important and should be at least 1.5mm², but to be

absolutely sure that the capacity of the reel is suitable for this

product and for others which may be used in the other output

sockets, we recommend the use of 2.5mm² section cable.

1. SAFETY INSTRUCTIONS

FUSE RATING 13AMP

Blue

Neutral

Wire

Yellow & Green

Earth Wire

Cable

Restraint

Brown

Live

Wire

Original Language Version

efs93.V4 Issue no.1 23/03/10

2. INTRODUCTION & SPECIFICATION

suitable for both large and small garages and workshops. excellent

as a back-up machine for garages with purpose-built fume extraction

units. complies with the latest eMc regulations and is powerful yet

quiet. suitable for small cars and commercials up to 10tonne GVW.

fitted with a exhaust pipe cone that includes a port to allow use with

gas analyser probes. supplied with 6mtr flexible ducting.

Specification:

Motor ........................................................................ 230V - 1ph 550W

Air flow ................................................................................560mtr³/hr

extraction height ............................................................ 120 to 750mm

Hose .............................................................................................. 6mtr

Weight ........................................................................................46.2kg