14. BASIC TESTER

A.

3-1/2" Gauge Head with dual readings - 0-145 psi & 0-1000

KPA (10 Bar). Can be used for all tests.

D.

Gauge Hose assembly with blow-down valve. Can be used

on all tests between the gauge and adaptors. Provides a

clean and convenient method of relieving pressure after

testing, or for a retest. Can also be used for observing

steadiness and volume of fuel.

Simply put end of clear tubing into proper container and

push the side button. Always make sure that the quick

couplers on all gauge and fitting snap firmly into place with

the locking sleeve in proper position.

AE. Low pressure 2-1/2" gauge with dual readings - 0-15psi &

0-1 kg/cm2 (1 Bar). Use for tests where an accurate

reading below 15 psi is required.

G.

CIS/TBI Test Hose - use when testing CIS or TBI Systems

where in-line connections are needed. Includes shut-off

valve for both control & primary system pressure checks.

We recommend that the D Gauge Hose is used with CIS

testing, as most manufacturers require that all air be purged

from the tester when running tests.

15. TEST PORT ADAPTOR

16. IN-LINE TESTING TBI

C.

Small Schrader type test hose with .308 x 32 thread.

Common applications - Ford EFI.

B.

Large Schrader type test hose with 7/16 x 20 thread.

Common applications include Chrysler, Jeep, and GM Test

Ports.

Always make sure that the quick couplers on all gauge, hoses, and fitting snap firmly into place with the locking sleeve in proper position.

Always make sure that the quick couplers on all gauge, hoses, and fitting snap firmly into place with the locking sleeve in proper position.

Always make sure that the quick couplers on all gauge, hoses, and fitting snap firmly into place with the locking sleeve in proper position.

V. . . . . . . . . . . . . . . . . . . . . . . . . . . . .5/8” x 18” Male Fitting

U. . . . . . . . . . . . . . . . . . . . . . . . .16mm x 1.5 Male Tube Nut

T. . . . . . . . . . . . . . . . . . . . . . .16mm x 1.5 Female Tube Nut

UB. . . . . . . . . . . . . . . . . . . . . . . .14mm x 1.5 Male Tube Nut

UA. . . . . . . . . . . . . . . . . . . . . .14mm x 1.5 Female Tube Nut

UC. . . . . . . . . . . . . . . . . . . . .14mm x 1.5 Female Tube Nut

S. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5/8” x 18 Union

VSE210 - 1 - 211204