Sealey DBG5010 User Manual

Dial bore gauge, Dbg5010, Instructions for

Advertising
background image

WARNING! Ensure Health and Safety, local authority and general workshop practice regualations are adhered to when using

tools and equipment.

DO NOT use the dial bore gauge if damaged.

DO NOT drop.

This is a precision instrument, always return gauge components to the internally lined storage case.

Maintain the gauge in good and clean condition for best and safest performance.

Keep the work area clean, uncluttered and ensure there is adequate lighting.

Ensure the work area floor is not slippery; wear non slip shoes.

Components to be measured and the dial bore gauge to be stored at room temperature (21°C).

InsTruCTIons For:

DIAL BORE GAUGE

ModEl no:

DBG5010

1. SAfETy

dBG5010 Issue: 1 - 08/04/14

Original Language Version

© Jack sealey limited

IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREfULLy. NOTE THE SAfE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE

PRODUCT CORRECTLy AND WITH CARE fOR THE PURPOSE fOR WHICH IT IS INTENDED. fAILURE TO DO SO MAy CAUSE DAMAGE AND/OR

PERSONAL INJURy AND WILL INVALIDATE THE WARRANTy. KEEP THESE INSTRUCTIONS SAfE fOR fUTURE USE.

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these

instructions, and properly maintained, give you years of trouble free performance.

2. INTRODUCTION

Precision mechanism with Ø55mm dial and locking rotating bezel, offering an accurate method of measuring a bore or detecting a taper or

ovality. Will indicate the deviation from set size by up to 1mm with an accuracy of 0.01mm. Included with the bore gauge are; probe body, dial

indicator, anvils, spacer rings. supplied in wooden storage case. .

3. SPECIfICATION

Model No: ............................................................................DBG5010

Measuring range: ...............................................................50-160mm

Maximum deviation Measurement (dial bore gauge): .................1mm

Maximum deviation Measurement (dial gauge separate): ..........5mm

dial Bezel diameter:................................................................Ø55mm

resolution:...............................................................0.01mm (0.0004")

4. CONTENTS

4.1. There are 5 main components-:

2

5

1

3

4

Item description

Qty

1

dial gauge indicator

1

2

Probe body

1

3

Clamp screw

1

4

distance piece (50mm)

1

5

Anvils and spacer rings

1-set