INSTRUCTIONS FOR:

PLATFORM SCAFFOLD STAND

Model No.

SSCL1.V2

TOWER EXTENSION PACK 3

Model No.

SSCL3

TOWER EXTENSION PACK 4

Model No.

SSCL4

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions

and properly maintained, give you years of trouble free performance.

IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR

PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

1. SAFETY INSTRUCTIONS

WARNING! Take care when using and moving scaffolding,

extended ladders and other such equipment in the vicinity

of power cables - risk of potentially fatal electric shock.

WARNING! Ensure Health and Safety, local authority, and

general workshop practice regulations are adhered to when

using this equipment.

3

Familiarise yourself with the application and limitations of the

scaffold, as well as the potential hazards.

3

Maintain the equipment in good condition.

7

DO NOT use the equipment if any parts are damaged or missing

as this may cause failure and/or personal injury.

3

Replace or repair damaged parts. Use genuine parts only.

Non-authorised parts may be dangerous and will invalidate the

warranty.

3

Keep the work area clean, uncluttered and ensure there is

adequate lighting.

WARNING! Use scaffold on level and solid ground and ensure

the brakes are applied and/or that the scaffold is anchored and

held firmly in place by some means.

WARNING! DO NOT erect or use the scaffolding on sloping or

unstable ground.

WARNING! Never over-reach when on the scaffolding.

3

Keep children and unauthorised persons away from the working

area.

7

DO NOT use the scaffolding for any purpose other than that for

which it is designed.

7

DO NOT allow children to climb the scaffolding.

7

DO NOT use the equipment when you are tired, under the

influence of alcohol, drugs or intoxicating medication.

3

When not in use store in a safe, dry, childproof area.

7

DO NOT use the equipment without side guardrails, knee rails

and toeboards fitted. Use all the components suppied.

3

When used outside, mobile scaffold towers should, wherever

possible, be secured to a building or other reliable structure.

3

It is good practice to tie in all scaffold towers of any height,

especially when left unattended or in exposed windy conditions.

Use only the recommended wall anchors.

3

Beware of strong wind conditions. Do not erect or use a

freestanding tower if the wind is likely to exceed 7.7 m/sec

(17mph or Beaufort force 4).

3

Take care when using mobile scaffold towers in hangers or

uncovered buildings as windforce may be increased due to

funnelling effects.

7

DO NOT climb a tower from the outside. Never climb on the

horizontal or diagonal braces. You should only climb the tower on

the inside using the ladder end frames.

7

DO NOT lean ladders against the tower. Never use ladders or

boxes to gain additional height.

7

DO NOT bridge between the mobile scaffold tower and buildings.

3

Stabilisers and ballast weights shall always be fitted where

specified. Ballast is used at the base to stabilise towers from

overturning. Ballast must be of solid material (i.e. NOT water or

loose sand) and should be positioned so as not to overload

individual legs. Ballast should be secured from accidental removal.

3

Keep equipment clean and inspect before and after use for

damage. Use serviceable equipment only. All working parts e.g.

castors, adjustable legs; stabiliser clamps should be lubricated

lightly with oil. Repairs should only be carried out by the supplier

or other competent person approved by the supplier.

3

Ensure that all personnel, tools and materials are removed from

the tower prior to moving it. Only move the scaffold tower

manually on a firm level surface, which is free of any obstacles.

2. INTRODUCTION

SSCL1.V2 EN1004 Approved Scaffold Tower System designed to meet

the UK PASMA T3 standards. Robust aluminium frame unit with

durable corrosion resistance. Heavy-duty platform with trap door for

safe access to platform. SSCL1 can be used as a 3mtr or 3.8mtr

working height platform by fitting extension kit supplied with the unit.

Unique design enables the unit to be quickly and easily folded down

without tools for transportation or storage. 860mm Width means unit

will pass through most doorways even when fully erected. Hand rails

for comfort and safety. Four large Ø125mm castors for easy mobility.

SSCL3 is an extension Kit for the SSCL1 Scaffold Tower System

Increases the platform height to 3.5mtr and the working height to

5.5mtr. Supplied with stability legs to stabilise unit and an extra trap

door platform.

SSCL4 is an extension Kit to be used with SSCL1 & SSCL3. Further

increases the platform height to 5.15mtr and the working height to

7.0mtr.

3. SPECIFICATION

Model No: ............................................................................... SSCL1.V2

Width: ........................................................................................... 860mm

Length:........................................................................................ 1780mm

Maximum Working Height: ................................................................ 3mtr

Maximum Platform Height: ............................................................. 3.8mtr

Weight: ...........................................................................................44.8kg

Model No: .....................................................................................SSCL3

Width: ......................................................................................... 1780mm

Width with support legs: ............................................................. 3810mm

Depth ............................................................................................ 860mm

Maximum Working Height: ............................................................5.5mtr*

Maximum Platform Height: ............................................................3.5mtr*

Maximum capacity ...........................................................................200kg

Weight: ..............................................................................................35kg

*Only when used with SSCL1

Model No: .....................................................................................SSCL4

Width: ......................................................................................... 1780mm

Width with support legs: ............................................................. 3810mm

Depth ............................................................................................ 860mm

Maximum Working Height: .......................................................... 7.0mtr**

Maximum Platform Height: ........................................................ 5.15mtr**

Maximum capacity ...........................................................................200kg

Weight: ..............................................................................................10kg

** Only when used with SSCL1 & SSCL3

Only move it longitudinally or diagonally. Do not exceed normal

walking speed. Raise the stabilisers 12 mm (½”) from the ground.

After moving re-lock the castors, check that the tower is level

and ensure that the stabilisers are secure and have a firm footing.

7

DO NOT exceed the safe working load of the platform. The

maximum capacity of the working platform for an evenly

distributed load is 1.5 kN/m² (according to HD1004 – scaffold

tower Class 2)

7

DO NOT jump on to or off the platforms.

7

DO NOT Do not use any lifting equipment on the mobile scaffold

tower.