Sealey LED130 User Manual

Led130.v2, Fig.1, Fig.2

Advertising
background image

instructions for:

130 led floodlight with wall

bracket - 230V

MoDEL no:

led130.V2

thank you for purchasing a sealey product. Manufactured to a high standard this product will, if used according to these instructions and

properly maintained, give you years of trouble free performance.

IMPORTANT: PleaSe read theSe iNStrUctioNS carefUllY. Note the Safe oPeratioNal reQUireMeNtS, warNiNgS, aNd

caUtioNS. USe thiS ProdUct correctlY, aNd with care for the PUrPoSe for which it iS iNteNded. failUre to do So

MaY caUSe daMage, or PerSoNal iNJUrY, aNd will iNValidate the warraNtY.

1. SafetY iNStrUctioNS

3. iNStallatioN & USe

1.1. electrical .
p

warNiNg! it is the user’s responsibility to read,

understand and comply with the following:

p

warNiNg! thiS ProdUct MUSt be iNStalled bY a

QUalified electriciaN.

You must check all electrical equipment and appliances to

ensure they are safe before use. You must inspect power

supply leads, plugs and all electrical connections for wear and

damage. You must ensure the risk of electric shock is

minimised by the installation of appropriate safety devices. An

rccB (residual current circuit Breaker) should be

incorporated in the main distribution board.

You must also read and understand the following instructions

concerning electrical safety:

1.1.1. Ensure the light is connected to an appropriate electrical on/off

switch.

1.1.2. Ensure the insulation on all cables and the product itself is

safe before connecting to the mains power supply.

1.1.3. Ensure that cables are always protected against short circuit

and overload.

1.1.4. regularly inspect power supply, leads, plugs and all electrical

connections for wear and damage, especially power

connections, to ensure that none are loose.

1.1.5. Important: Ensure the voltage marked on the product is the

same as the electrical power supply to be used.

1.1.6.

do Not pull power cable once installed.

1.1.7.

do Not pull power plugs from sockets by the power cable.

1.1.8.

do Not use worn or damaged leads, plugs or connections.

immediately replace or have repaired by a qualified electrician.

Ensure the unit is correctly earthed and wired according

to fig.1 below.

a) Connect the gREEN/YEllOw earth wire to the earth

terminal ‘E’.

b) Connect the bROwN live wire to live terminal ‘l’.

c) Connect the bluE neutral wire to the neutral terminal ‘N’.

After wiring, check there are no bare wires, that all wires

have been correctly connected and that the cable clamp

is tight. Also ensure that the mains cable passes through

the rubber washer situated behind the cable entry nut.

1.2. geNeral SafetY.

p

warNiNg! turn off the mains power supply before

servicing or performing any maintenance.

3

Maintain the light in good condition (repairs must only be

undertaken by a qualified electrician).

3

replace or repair damaged parts. use recommended parts

only, non authorised parts may be dangerous and will invalidate

the warranty.

3

Ensure the light is installed correctly in accordance with these

instructions.

3

only install the light on a vertical surface.

do Not fix the light

on any horizontal surface, i.e. ceiling, or overhang.

p

daNger! do Not direct the light into a person's eyes.

this unit has a very intensive light output, which if

incorrectly used could cause eye damage.

7

do Not install the light where it is likely to be knocked or hit.

7

do Not install in bathrooms, shower rooms, saunas or such

locations.

7

do Not use the light without the front glass shield.

Original Language Version

LED130.V2 issue: 1 - 03/05/12

2. iNtrodUctioN & SPecificatioN

Mounted in die-cast aluminium housing fitted with wall bracket.

features 130 super bright LEDs, which have a longer working life

than traditional halogen bulbs. Low wattage means a low energy

consumption which helps to reduce energy bills. supplied without

mains cable and suitable for outdoor mounting.

Power . . . . . . . . . . . . . . . . . .8W

Lumen output. . . . . . . . . 585lm

supply. . . . . . . . . . . . . . . . 230V

fig.1

3.1. iNStallatioN.

p

warNiNg! ensure the unit is

not connected to the mains

power supply before installation.

3.1.1. consider the position of the unit to

ensure you obtain maximum

benefit from the lighting, and that

an appropriate electrical power

source can be provided.

3.1.2. the light must be mounted

vertically only, i.e. on a wall etc.

do Not mount horizontally,

i.e.ceiling or overhang,

do Not

mount so that the face of the lamp

is pointing upwards, or is facing towards the mounting surface.

3.1.3. this LED floodlight develops minimal heat and is not subject to

the same mounting restrictions that apply to halogen lamps

that become too hot to touch. We do however recommend that

the floodlight should not be placed in cramped or restrictive

positions and should be fixed at the following minimum

distances between the light and any surface/object: (see fig.2)

● 500mm minimum between the top of the light and any

overhead surface, or objects, i.e. ceilings, overhangs.

● 200mm between sides of light and end or side walls, surface

or objects.

● 2 metres minimum between the front of the light and any

object to be illuminated.

3.1.4. fix the light to vertical surface with appropriately strong screws

or bolts.

3.1.5. Ensure the unit is connected to the electrical supply by a

qualified electrician.