1. safetY instructions

4. installation instructions

2. introduction

3. specification

fig 1.

fig 2.

Original Language Version

MD520c.V2 issue: 1 - 07/01/11

1.2. general safetY.

warning! turn off the mains power supply before changing

tubes, servicing or performing any maintenance.

Maintain the light in good condition (repairs must only be undertaken

by a qualified electrician).

replace or repair damaged parts. use genuine parts only, non

authorised parts may be dangerous and will invalidate the warranty.

Ensure the light is installed correctly in accordance with these

instructions.

only install the light on a vertical surface. Do not fix the light on any

horizontal surface i.e. ceiling, or overhang.

Light becomes very hot. installation must be away from flammable or

combustible materials such as wood, cloth, paper etc.

danger! do not direct the light into a persons eyes. this unit

has a very intensive light output, which if incorrectly used could

cause eye damage.

Do not install the light where it is likely to be knocked or hit.

Do not install in bathrooms, shower rooms, sauna or such locations.

Do not install near an exhaust outlet. i.e. Boiler flue, dryer outlet, etc.

Do not touch the light when operating, allow to cool before touching,

light operates at high temperature.

Do not handle halogen bulbs as the natural oil from your fingers and

hands will shorten the bulb life. Handle only with a soft cloth.

Do not use the light without the front glass shield. Avoid touching the

glass shield as handling may reduce its serviceable life and cause the

glass to crack.

Do not use the light near flammable, combustible or explosive

liquids, solids, gases or equipment.

specifications:

Power: .....................................................................................................230Volt.

Bulb: ................................................................400Watt tungsten/Halogen tube.

Detection Angle: ..................................................................... 120° (fan shape).

Detection range: ..................................................................... 12m (Adjustable).

time Delay: .............................................6 seconds to 20 minutes (Adjustable).

Light sensitivity: .................................................................. 30 Lux (Adjustable).

replacement tube: .............................................................................. ML400B.

1.1. electrical.

WArninG! it is the user’s responsibility to read, understand and

comply with the following:

WArninG! tHis ProDuct Must BE instALLED BY A QuALifiED

ELEctriciAn.

You must check all electrical equipment and appliances to ensure they

are safe before using. You must inspect power supply leads, plugs and

all electrical connections for wear and damage. You must ensure the risk

of electric shock is minimised by the installation of appropriate safety

devices. An rccB (residual current circuit Breaker) should be

incorporated in the main distribution board. You must also read and

understand the following instructions concerning electrical safety.

1.1.1. Ensure the light is connected to an appropriate electrical on/off switch.

1.1.2. Ensure the insulation on all cables and the product itself is safe before

connecting to the mains power supply.

1.1.3. Ensure that cables are always protected against short circuit and

overload.

1.1.4. regularly inspect power supply, leads, plugs and all electrical

connections for wear and damage, especially power connections, to

ensure that none are loose.

1.1.5. Important: Ensure the voltage marked on the product is the same as

the electrical power supply to be used.

1.1.6. Do not pull power cable once installed.

1.1.7. Do not pull power plugs from sockets by the power cable.

1.1.8. Do not use worn or damaged leads, plugs or connections.

immediately replace or have repaired by a qualified Electrician.

Ensure the unit is correctly earthed and wired according to the

diagram figure 1 below.

a)

Connect the gREEN/YEllOw earth wire to the earth terminal ‘E’.

b)

Connect the bROwN live wire to live terminal ‘l’.

c)

Connect the bluE neutral wire to the neutral terminal ‘N’.

After wiring, check there are no bare wires, that all wires have been

correctly connected and that the wire restraint is tight.

infrared detector unit automatically switches 400Watt tungsten/halogen lamp on

when approached by vehicles or persons. Detects movement and heat and is

fitted with adjustable sensitivity and light duration controls. supplied with wall

mounting bracket and full operating instructions. supplied without mains cable

and suitable for outdoor mounting.

warning! do not connect unit to the mains power supply

before installation. when ready, the lamp must only be connected

to the mains by a qualified electrician.

4.1. fitting

Give careful consideration to the position of unit to ensure you obtain

maximum benefit from the lighting range, and that an appropriate

electrical power source can be provided.

4.1.1 Do not install near an exhaust outlet. i.e. Boiler flue, dryer outlet, etc

as variance in temperature will effect the sensitivity of light. the light

must be mounted on a vertical surface only i.e. on a wall etc.

Do not mount on a horizontal surface i.e. ceiling or an overhang,

Do not mount so that the face of the lamp is pointing upwards, or is

facing towards the mounting surface. An approximate appropriate

mounting height from the ground is 2.5m.

4.1.2 to protect surfaces and objects from the light’s heat, fix at following

minimum distances between light and any surface/object, (fig 2A).

500mm minimum between the top of the light and any overhead

surface, or objects, i.e. ceilings, overhangs. 200mm between sides of

light and end or side walls, surface or objects. 2 metres minimum

between the front of the light and any object to be illuminated.

fix the light to vertical surface with appropriate fixings. Do not tilt the

light back beyond 30° (fig 2B) or forward more than 45° (fig 2c).