7. WATER DRAINAGE

8. MAINTENANCE

7.1. EMPTYING THE INNER TANK. When the inner tank becomes full the temperature display (fig.6.10) will show

'E4'

7.1.1. The compressor will shut down and the control panel will become inoperative until the tank is emptied.

7.1.2. Disconnect the machine from the mains supply.

7.1.3. Place a suitable container below the water outlet at the back of the machine.

7.1.4. Pull out the rubber plug (fig.8) and allow the tank to drain. Remove and empty the collection container. Refit the

rubber plug.

7.1.5 Plug the machine back into the mains supply and restart it.

WARNING! Switch off the machine and unplug it from the mains power supply before performing any

maintenance or repairs.

8.1. CLEANING.

8.1.1. Remove the plug from the mains power supply.

8.1.2. Use a soft, damp cloth to clean the machine outer casing. Don't use chemical agents such as benzene, alcohol,

petrol, lighter fuel etc. as these agents may melt / damage the surface of the plastic.

8.1.3.

DO NOT splash water into the machine.

8.2. FILTER.

8.2.1. Clean the filters every two weeks as blocked filters will seriously reduce the efficiency of the machine.

8.2.2 There are two filters situated at the back of the machine.

8.2.3. Clean the filters in warm water with a neutral detergent. Allow them to dry completely before refitting them.

8.2.4. Do not run the machine without filters.

8.3. SEASONAL CLEANING AND STORAGE

8.2.1. If the machine will be unused for a long period of time, prepare it in the following way.

8.2.2. Empty the internal water tank as described in 7.1.

8.2.3.. Run the machine in fan mode for two hours to dry out the internal machinery.

8.2.4. Turn the machine off and unplug it from the mains power supply.

8.2.5. Remove the filters, clean, dry and reinstall them.

8.2.6. Disconnect the exhaust duct.

8.2.7. Cover the machine with a plastic bag and store in a dry, childproof location

© Jack Sealey Limited

fig.8

9. TROUBLESHOOTING

PROBLEM

CAUSE

SOLUTION

Machine not working

Power OFF

Plug in / turn on power

'E4' shows on temperature indicator

Drain inner water tank (see 7.1)

Timer set

Turn off machine for three minutes

then restart it

Machine auto restarts frequently

Machine in direct sunlight

Shade machine / draw curtains

Doors and windows are open, many heat

sources in room

Close doors and windows, remove

heat sources from room

Filters too dirty

Clean or replace filters

Air inlets or air outlet is blocked

Remove blockage

Machine too noisy

Machine is not situated on level ground

Move to flat and solid ground

Compressor not working

Compressor heat protection cut out

operated

Wait for 3 minutes, restart the

machine when temperature normal

SAC9000.V3 Issue: 4(I) - 14/02/14