Everpure PBS400 User Manual

Page 3

Advertising
background image

Label

Lug

6

J

K

L

M

N

O

Q

5

BASIC INSTALLATION INSTRUCTIONS

continued

Attach Filtered Water To Cold Line of Faucet

Attach open end of existing Braided Tubing to Union Fitting on

outlet side (right) of new Filter Head. Hand tighten to avoid damage

to fittings.

Install And Flush Filter Cartridge

Lift handle of the build-in shut off (QC Valve) on the Head.
Hold Head firmly with one hand.
Align cartridge lug with label on filter Head.
Insert filter Cartridge—Push upwards.
Turn it to the right—About 1⁄4 turn—Until rotation stops.
Open cold water valve and check for leaks up to Inlet Elbow Fitting.
Open Water Faucet (not pictured).
Lower the QC Valve Handle to flush water to the sink.

NOTE: Flush new filter cartridges for at least 3 minutes to remove air

and any loose carbon. At first the water may appear cloudy due to

trapped air in the filter and tubing. If water continues to be cloudy for

more that one week, please contact Everpure Technical Services for

assistance: (800) 942-1153

Remove plastic wrapper and pull Tab from back of Everpure Filter

Timer. The LED and buzzer will cycle 3 times to confirm the start.

It is programmed to flash and sound again in 11 months. Remove

adhesive backing and mount Timer in a convenient location under

the sink.

5.

I.

6.

J.
K.
L.
M.
N.
O.
P.
Q.

R.

I

Label

Lug

6

J

K

L

M

N

O

Q

•  •

E

N

G

L

IS

H

5

NOTES

Reduces limescale build-up in water-using appliances as tested

by Everpure
This installation must comply with all applicable state and local

regulations.
Do no use with water that is microbiologically unsafe or unknown quality

without adequate disinfection before or after the system.