WARNING! Ensure health & safety, local authority, and general workshop practice regulations are strictly adhered to when using this

equipment.

Familiarise yourself with product application and limitations, as well as the specific potential hazards peculiar to this product.

Maintain the meter in good condition (use an authorised service agent).

Replace or repair damaged parts. Use genuine parts only. Non authorised parts

will invalidate the warranty.

Use only to meter water/urea solutions.

Ensure safety eye protection and protective clothing are worn when using this product.

Keep the work area clean, uncluttered and ensure there is adequate lighting.

Maintain correct balance and footing. Ensure the floor is not slippery and wear non slip shoes.

Keep children and unauthorised persons away from the working area.

After use, drain any fluids from the equipment before storage.

Dispose of waste liquids in accordance with local authority regulations.

DO NOT exceed the maximum pressure of 10bar.

DO NOT use the equipment near open flames.

DO NOT smoke whilst using this equipment.

DO NOT use for corrosive fluids.

DO NOT dismantle, tamper with or adapt the equipment for any purpose other than for which it is designed.

DO NOT use the unit if it has been dropped or mishandled, check the unit to ensure there is no damage.

DO NOT use taper connections, use parallel connectors only.

DO NOT use compressed air on the turbine, the excessive rotation will damage the unit.

Keep the meter clean and store in a safe dry, childproof location.

WARNING! DO NOT allow uncontrolled discharge of fluids thus polluting the environment. All liquids must be disposed of according to

local authority regulations.

InstRUctIons FoR:

DIGITAL FLOW METER -

ADBLUE®

MODEL No:

ADB02

1. SAFETY INSTRUCTIONS

2. INTRODUCTION

3. INSTALLATION

IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS,

WARNINGS AND CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS

INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY.

PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE USE.

thank you for purchasing a sealey product. Manufactured to a high standard this product will give you years of trouble free performance

if these instructions are carefully followed and the product is correctly maintained.

ADB02

Issue no: 1 - 21/06/13

Robust rubber housing with integral digital electronic metering. Easy

to read large, four digit, 28mm high LcD display calibrated in litres.

Features flow rate indication. 1”x1”BSP Male / Female fittings.

suitable for use with AdBlue

®.

Powered by 2 x AAA batteries (supplied). IP65 Rated protection.

Measurement system

Turbine (Polypropylene)

Flow Rate (Range)

5~ 100 ltr/min

operating pressure (Max) 10bar
Bursting pressure (Min)

40bar

storage temperature

(Range)

-20°c to 70°c

storage humidity (Max)

95%

operating temperature

(Range)

-10°C to 50°C

Flow resistance

0.30bar at 100 lltr/min

Viscosity (Range)

2 to 5.35 cSt

Accuracy

(between 15 and 120l/min)

+/-1% of value indicated after calibration

Reproducibility (typical)

+/- 0.3%

Power supply

2 x 1.5V AAA alkaline batteries

Battery life

18 to 36 months

Weight

0.25kg (including batteries)

compatible Fluids

Water, Urea

3.1

Installing Into System

3.1.1 connect the ADB02 into the system, ensuring that the arrow

on the side of the meter is pointing in the direction of the flow.

Note: Use 1" BSP threaded connectors only, DO NOT use taper

threaded connectors.

Note: To improve the life of the turbine, a strainer should be fitted

upstream of the meter.

3.1.2 the facia of the meter can be rotated to match the orientation

of the meter (fig.1). Remove the four screws from the front of

the unit and carefully separate from the rubber protection

surround, rotate the facia to the desired position taking care

not to trap the wires against the reed switch (fig.2.1), push

gently into the rubber surround and refit the screws.

fig.1