Sealey TP89 User Manual

Self priming piston pump, Tp89, Safety instructions

Advertising
background image

3.1.1 Insert the spout ‘D’ into the head of the pump and secure with hose clip.

3.1.2 Attach the extension tubes together with the connector ‘J’ and secure with

hose clips ‘H’. Attach extension tubes to main pump and secure.

3.1.3 When fitting to 3/4” diameter inlet, unscrew and remove the 2” adapter ‘G’, when using a

2” inlet replace the adaptor.

3.2.1 Screw the pump onto the drum/container.

3.2.2 The pump stroke can be set at 40, 80, 140 or 200ml per stroke using the

sleeves provided ‘B/C’. Unscrew the handle ‘A’ and slide the sleeves over the shaft,

replace the handle.

InSTrUCTIonS for:

SELF PRIMING PISTON PUMP

MoDEL no :

TP89

IMPorTAnT: PLEASE rEAD THESE InSTrUCTIonS CArEfULLY. noTE THE SAfE oPErATIonAL rEQUIrEMEnTS,

WArnInGS & CAUTIonS. USE THE ProDUCT CorrECTLY AnD WITH CArE for THE PUrPoSE for WHICH IT IS

InTEnDED. fAILUrE To Do So MAY CAUSE DAMAGE AnD/or PErSonAL InJUrY AnD WILL InVALIDATE THE

WArrAnTY. PLEASE KEEP InSTrUCTIonS SAfE for fUTUrE USE.

WARNING! DO NOT operate using flammable liquids in a

confined space, the area should have adequate

ventilation.

3

If pumping flammable liquids, avoid proximity to naked

flames or welding operations.

3

Wear appropriate protective clothing when pumping solvents. We recommend

eye/face and hand protection, available from your authorised Sealey dealer.

3

Ensure Health & Safety, local authority, and general workshop practice

regulations are adhered to when using this equipment.

3

Ensure spillages are dealt with immediately. failure to do so could lead to

personal injury or damage to the environment and possible prosecution by the

authorities.

3

Keep children away from areas where solvents are being used.

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component

parts without prior notice.

IMPORTANT: no liability is accepted for incorrect use of this product. WARRANTY: Guarantee is 12 months from

purchase date, proof of which will be required for any claim.

INFORMATION: for a copy of our catalogue and latest promotions call us on

01284 757525 and leave your full name, address and postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor

Sealey Group,

Bury St. Edmunds, Suffolk.

www.sealey.co.uk

Web

email

1. SAFETY INSTRUCTIONS

Thank you for purchasing a Sealey Product. Manufactured to a high standard this product will, if used according to these instructions and

properly maintained, give you years of trouble free performance.

3. ASSEMbLY / OPERATION

TP89 Issue no: 1 - 10/03/09

2. SPECIFICATION

Self-priming, piston pump fitted with anti-drip nozzle and 2”BSP adaptor and dip-tube.

Suitable for oils, antifreeze, degreasants and other non-corrosive fluids. Unit will

deliver 200ml per stroke but by using the two sleeves supplied, delivery can be limited

to 40, 80 or 140ml per stroke. Will fit most containers and drums from 25-205ltr.

Sleeve Combination

Per Stroke

no Sleeve

200ml

Small Sleeve (C)

140ml

Long Sleeve (B)

80ml

Both long and short sleeve

40ml

3.2.3 raise and compress the handle, fluid should begin to flow after 3 strokes.

3.2.4 After fluid transfer put the cap ‘E’ on the end of the spout to prevent dripping.

Advertising