InstructIons for:

DIESEL/FLUID TRANSFER PUMP

MoDEL no's:

TP96.V2 & TP9624.V2

thank you for purchasing a sealey product. Manufactured to a high standard this product will, if used according to these instructions

and properly maintained, give you years of trouble free performance.

IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND

CAUTIONS. USE THIS PRODUCT CORRECTLY AND ONLY FOR ITS INTENDED PURPOSE. FAILURE TO DO SO MAY CAUSE DAMAGE

OR PERSONAL INJURY, AND WILL INVALIDATE THE WARRANTY. RETAIN THESE INSTRUCTIONS FOR FUTURE USE.

Maintain the pump in good condition (use an authorised service agent).

replace or repair damaged parts. Use recommended parts only. Non

authorised parts may be dangerous and will invalidate the warranty.

Keep the pump clean for best and safest performance.

Ensure the power supply (vehicle battery) corresponds with the requirements

of the pump. tP96.V2 12Volt, tP9624.V2 24Volt Dc power supply.

Ensure that there is more liquid in the suction tank than will be pumped.

Ensure that the capacity of the receiving tank is sufficient to hold the pumped

fuel.

Wear safety goggles and gloves, and protective clothing when working

around fuel. A full range of personal safety equipment is available from your

local sealey dealer.

use the pump in an appropriate working area for its function.

Keep area clean and tidy and free from unrelated materials, and ensure there

is adequate lighting.

Maintain correct balance and footing. Ensure the floor is not slippery and

wear non slip shoes.

Keep children and unauthorised persons away from the working area.

DO NOT ‘dry run’ the pump without fuel. this will damage the pump’s internal

components and will invalidate your warranty.

DO NOT operate the pump continuously for more than 30 minutes. the duty

cycle of the unit is 30 minutes, after which the motor must be left to cool

down.

DO NOT run the unit for more than 2-3 minutes with the delivery nozzle

closed.

DO NOT start or stop the pump by connecting or disconnecting the battery

clamps.

DO NOT operate the pump with wet hands.

DO NOT use the pump where explosive or flammable vapours may be

present.

DO NOT tamper with the pump connections.

WARNING! DO NOT use the unit to pump the following fluids: Petrol,

inflammable liquids with PM <55°C, water, alimentary liquids with

viscosity >20 cSt., corrosive chemicals and solvents.

1. SAFETY INSTRUCTIONS

tP96.V2, tP9624.V2 Issue no: 1 - 30/04/12

fig.1

Original Language Version

Model TP96.V2

Voltage . . . . . . . 12V

speed . . . . . . . . 2600rpm

current . . . . . . . 22A

Power . . . . . . . . 260W

fuse . . . . . . . . . 25A

Duty cycle. . . . . 30min/hr

flow rate . . . . . 43ltr/min

Model TP9624.V2

Voltage . . . . . . . 24V

speed . . . . . . . . 2600rpm

current . . . . . . . 13A

Power . . . . . . . . 160W

fuse . . . . . . . . . 15A

Duty cycle. . . . . 30min/hr

flow rate . . . . . 46ltr/min

2. INTRODUCTION

Electric 12 or 24V pump with battery clips. Suitable for filling diesel vehicles in the field. Self-priming unit delivers up to 43ltr a minute of fluid

for TP96 and 46ltr a minute of fluid for TP9624. Supplied with 4mtr of hose and TP108 Manual Delivery Nozzle. Includes on/off switch, carry

handle, mounting plate and suction hose filter.

3. ASSEMbLY

WARNING! use the pump fittings provided for connecting the suction and delivery tubes to the inlet and outlet ports of the pump.

3.1 Before using the pump, unpack all materials and inspect the pump unit for damage.

3.2 connect the wires from the pump motor (fig.2-1) to the switch housing (fig.2-2) as shown in fig.1 and insert the fuse into the fuse holder.

Attach the switch housing (fig.2-2) to the pump motor (fig.2-1) using the four screws provided. Ensure that the 'o' ring seal is fitted

between the switch housing and the pump motor.

3.3 A mounting bracket is supplied (fig.2-4) which can be attached to the lower end of the inlet/outlet casting (fig.2-5) using the socket cap

screws provided. the pump can be mounted in either a horizontal or a vertical axis, refer to fig.3. Ensure that the pump is mounted so

that the on/off switch is visible and readily accessible.