Fig.4, Introduction & specification, Preparation & assembly – Sealey SAC0610E User Manual

Page 2: Fig.3 fig.1

Advertising
background image

2. INTRODUCTION & SPECIFICATION

Compact and portable compressor, suitable for use with the Sealey

range of air nailers, tyre inflators and air brushes. Fitted with twin

gauges displaying tank and working pressures. Features four

anti-vibration feet for added stability when in use. Complies with

current European standards.

3. PREPARATION & ASSEMBLY

3.2.

Confirm that the mains voltage corresponds with the voltage

shown on the compressor data plate.

3.3.

The compressor should be installed on a flat surface, or one

that does not exceed 10

° either transversely or longitudinally,

and should be in a position that allows good air circulation

around the unit.

3.4.

The compressor is supplied without oil in it. The oil is in a

separate container. Remove the transit plug from the oil filler

aperture, pour oil into the aperture until it has reached the

correct level on the sight glass (fig.2B). Fit the oil filler/

breather (fig.2A) supplied into the aperture.

DO NOT ATTEMPT TO RUN THE COMPRESSOR UNTIL

THIS HAS BEEN DONE.

3.5.

Ensure that the air vent in the oil filler/breather is free

from debris. If the air vent is blocked, pressure can build

up in the crankcase causing damage to the compressor

and possible personal injury.

3.6.

Screw air filter (fig.3C) into inlet port.

3.7.

Regulator assembly. See fig.4. Remove any packing

material from the connector attached to the pressure switch.

Check that the connector thread has a factory applied

sealant to prevent leaks. Thread the regulator assembly onto

the connector making sure that it is properly aligned to avoid

cross threading. The assembly should rotate approximately 6

to 7 revolutions. The two gauges should be facing in the

same direction. Do not overtighten.

WARNING! The compressor is supplied with lubricating oil

in the pump - see para. 3.4.

3.1.

Remove compressor from packaging and inspect for any

shortages or damage. If anything is found to be missing or

damaged contact your supplier.

fig.4

MODEL ......................................................................... SAC0610E.V2

Motor output .................................................................................1hp

Voltage/phase ......................................................................... 230V/1

Rated supply .................................................................................13A

Air displacement .......................................................4.7cfm-113ltr/m

Maximum Free air delivery .........................................2.7cfm-76ltr/m

Tank capacity .................................................................................6ltr

Max pressure .................................................................116psi / 8bar

Weight .....................................................................................14.46kg

Dimensions (W x D x H) .....................................400 x 175 x 430mm

fig.3

fig.1

C

fig.2

A

B

Original Language Version

SAC0610E.V2 Issue No:2(I)- 08/04/14

© Jack Sealey Limited

3

Read the instructions relating to any accessory to be used

with this compressor. Ensure the safe working pressure of any

air appliance used exceeds compressors output pressure. If

using a spray gun, check that the area selected for spraying is

provided with an air change/ventilation system.

3

Ensure the air supply valve is turned off before disconnecting

the air supply hose.

3

To move the compressor use the handle only. Maintain unit’s

centre of gravity when lifting.

DO NOT attempt to lift or move

the compressor by any other means.

3

Use the compressor in a well ventilated area and ensure it is

placed on a firm surface.

3

Keep tools and other items away from the compressor when

it is in use, and keep area clean and clear of unnecessary

items.
3

Ensure the air hose is not tangled, twisted or pinched.

3

Keep children and unauthorised persons away from the

working area.

7

DO NOT disassemble compressor for any reason. The unit

must be checked by qualified personnel only.

7

DO NOT use the compressor outdoors, or in damp, or wet,

locations.
7

DO NOT operate within the vicinity of flammable liquids,

gases or solids.

7

DO NOT touch compressor cylinder, cylinder head or pipe

from head to tank as these may be hot.

7

DO NOT use this product to perform a task for which it has

not been designed.

7

DO NOT deface the certification plate attached to the

compressor tank.

7

DO NOT cover the compressor or restrict air flow around the

unit whilst operating.

q

DANGER! DO NOT direct the output jet of air towards people

or animals.

7

DO NOT operate the compressor without an air filter.

7

DO NOT allow anyone to operate the compressor unless they

have received full instructions.

WARNING! The air tank is a pressure vessel and the following

safety measures apply:

7

DO NOT tamper with the safety valve, DO NOT modify or alter

the tank in any way and

DO NOT strap anything to the tank.

7

DO NOT subject the tank to impact, vibration or to heat and

7

DO NOT allow contact with abrasives or corrosives.

3

Drain condensation from tank daily and inspect inside walls

for corrosion every three months and have a detailed tank

inspection carried out annually. The tank shell must not fall

below the certified thickness at any point.

WARNING! If an electrical fuse blows, ensure it is replaced

with an identical fuse type and rating.

3

When not in use, store the compressor carefully in a safe,

dry, childproof location.

Advertising