In order to keep the compressor in good working condition,

periodic maintenance is essential.

IMPORTANT! Failure to carry out maintenance tasks may

invalidate the warranty on your compressor.

WARNING! Before performing any maintenance operation,

switch off the compressor, disconnect from electricity

supply and release all air from the tank (except for 5.3.a)

5.1. Operations to be carried out after the first 50 working hours:

a) Check that all bolts/nuts are tight, particularly those retaining

the crankcase and cylinder head.

b) Replace the lubricating oil - see para 5.5.a. shown in fig.4.

5.2. Operations to be carried out weekly:

a) Drain condensation by opening the valve located under the

tank (fig.7). Place a container under the valve and open the

valve by turning anti-clockwise.

WARNING! Take care if there is still pressure inside the cylinder

as water could flow out with considerable force.

Recommended pressure 1 - 2bar max.

b) Check oil level and, if necessary, top up.

5.3. Operations to be carried out every 50 hours

(or more frequently, if the compressor operates in a very

dusty atmosphere):

a)

Remove the air filter element (fig.4). Using stored air from

the compressor's tank, clean the filter with compressed air.

(Wear eye protection and

DO NOT direct air towards the

body or hands).

DO NOT operate the compressor without

the filter as foreign bodies or dust could seriously damage

the pump. Replace the filter element and air filter housing.

b) Check for oil leaks.

5.4. Operations to be carried out every 100 hours:

a) Check the automatic cut-out at max. pressure and the

automatic cut-in at 2bar below.

5.5. Operations to be carried out every 400 hours:

a) Replace the lubricating oil. (Refer to fig.4) For oil

specifications see 5.7.

Remove the oil filler, then remove the oil drainer plug

draining the oil into a container. Drain when the

compressor is hot so that the oil drains rapidly and completely.

Replace oil drain plug and refill through the oil filler.

DO

NOT overfill (check level at oil level window, red dot denotes

correct level.) Replace oil filler.

WARNING! Never mix different oils and DO NOT use non-

detergent/low quality oils as the compressor may be damaged.

WARNING! Dispose of waste oil only in accordance with

local authority requirements.

b) Replace air filter. (See fig.6)

c) Check all tube fittings and electrical connections.

d)

Inspect pressure tank inside and out for damage or corrosion.

Maintenance Operations

Weekly 50hrs

100hrs

400 hrs

Drain condensation

Check oil level

Clean intake filter

Check for oil leaks

Replace oil

Check cut-out

General cleaning of

compressor

Replace air filter

Check tube fittings and

electrical connections

Original Language Version

© Jack Sealey Limited

SAC55075B Issue: 1 - 24/12/14

5. MAINTENANCE

5.6. Maintenance Schedule

4.3. STARTING THE COMPRESSOR

4.3.1 Check that the ON/OFF switch (fig.5) is OFF in the "O" position.

4.3.2 Plug mains lead into mains supply and start the compressor by

moving the pressure switch to the ON ‘I’ position.

Check the

direction of rotation (see arrow on cylinder head cover) to

confirm correct wiring of 3-phase plug.

4.3.3 When starting the compressor for the first time, leave it running

with no air tools connected to the air outlet. Make sure that

pressure in the tank rises and that the compressor stops

automatically when the maximum pressure value allowed -

written on the plate and shown on the gauge is achieved.

The compressor will now operate automatically.

The pressure switch stops the motor when the maximum

tank pressure is reached and restarts it when the pressure

falls below the minimum threshold.

4.3.4 Stop the compressor by moving the pressure switch (fig.2) to

the

"O" position. The compressed air inside the compressor

head will flow out, making the restart easier and preventing the

motor from being damaged.

DO NOT, other than in an

emergency

, stop the compressor by switching off the mains

power, or by pulling the plug out, as the pressure relief will not

then operate and motor damage may result upon restart.

When the compressor runs correctly and is stopped correctly

there will be: (a) a whistle of compressed air when the motor

stops. (b) a protracted whistle (about 20-25 seconds) when the

compressor starts with no pressure in the tank.

WARNING! For this reason DO NOT tamper with, or adjust,

the switch or safety valve.

fig.5

4.2. Operation

WARNING! Ensure that you have read, understood and

apply Section 1 Safety Instructions.

IMPORTANT! The use of extension leads not

recommended as the resulting voltage drop reduces

motor, and therefore pump performance, and could cause

damage to the compressor.

NOTE: Take care when selecting tools for use with the

compressor. Air tool manufacturers normally express the

volume of air required to operate a tool in cubic feet per

minute (cfm). This refers to free air delivered by the

compressor (‘air out’) which varies according to the pressure

setting.

DO NOT confuse this with the compressor

displacement which is the air taken in by the compressor (‘air

in’). ‘Air out’ is always less than ‘air in’ due to losses within the

compressor.