Introduction 3. specifications – Sealey SACV42755B User Manual

Page 2

Advertising
background image

1.1.10.

This product must be fitted with a 3-phase plug according to the diagram, and will require a

minimum of 16Amps per phase, (preferably 32Amp) electrical supply. You must contact a

qualified electrician to ensure an appropriately fused supply is available.

Connect GREEN/YELLOW wire to earth (E) terminal.

Connect the live wires to live 1, 2 and 3. Check for the correct direction of rotation

(see arrow on belt cage) to confirm correct wiring of 3-phase plug when you first run the

compressor.

When completed, check that there are no bare wires, that all wires have been connected

correctly, that the cable external insulation extends beyond the cable restraint and that the

restraint

is

tight.

1.2

GENERAL SAFETY INSTRUCTIONS

3

Familiarise yourself with the application and limitations of the compressor.

3

Ensure that the compressor is in good condition before use. If in any doubt do not use the unit and

contact an electrician/service agent.

IMPORTANT! The compressor must be installed and commissioned by qualified personnel.

WARNING! Compressor must only be serviced by an authorised agent. DO NOT tamper with, or

attempt to adjust, pressure switch or safety valve.
3

Before moving or maintaining the compressor ensure it is unplugged from the mains supply and that the air tank pressure has been vented.

3

Only use recommended attachments and parts. To use unauthorised items may be dangerous and will invalidate your warranty.

3

Read the instructions regarding any accessory used with the compressor. Ensure the safe working pressure of any air appliance used

exceeds the compressor regulator. If using a spray gun, check the area selected for spraying is provided with an air change system or

ventilation.
3

Ensure the air supply valve is turned off before disconnecting the air supply hose.

3

Use the compressor in a well ventilated area and ensure it is placed on a firm surface away from any heat sources

2. INTRODUCTION

3. SPECIFICATIONS

3

Keep tools and other items away from the compressor when it is in use and keep area clean and clear of unnecessary items.

3

Ensure the air hose is not tangled, twisted or pinched.

3

Keep children and unauthorised persons away from the working area.

7

DO NOT disassemble compressor for any reason. The unit must be checked by qualified personnel only.

7

DO NOT use the compressor outdoors, or in damp, or wet, locations and DO NOT operate within the vicinity of flammable liquids, gases or

solids.
7

DO NOT touch compressor cylinder, cylinder head or pipe from head to tank as these may be hot and will remain so for some time after

shutdown.
7

DO NOT attempt to move the compressor by pulling the air tool hose.

7

DO NOT use this product to perform a task for which it has not been designed.

7

DO NOT operate the compressor with the belt guard removed.

7

DO NOT deface the certification plate attached to the end of the compressor tank.

7

DO NOT cover compressor or restrict air flow around the machine whilst operating.

DANGER! DO NOT direct the output jet of air towards people or animals.

7

DO NOT operate the compressor without an inlet air filter.

7

DO NOT allow anyone to operate the compressor unless they have received full instructions and adequate training.

WARNING! The air tank is a pressure vessel and the following safety measures apply:

7

DO NOT tamper with the safety valve and DO NOT modify or alter the tank in any way, DO NOT strap anything to the tank.

7

DO NOT subject the tank to impact, vibration or to heat and DO NOT allow contact with abrasives or

corrosives.
7

No welding operations are to be carried out on any pressurised parts of the vessel.

3

DO drain condensation from tank daily, inspect inside walls for corrosion every three months and have a detailed tank inspection

carried out annually. Tank shell must not fall below the certified thickness at any point.

WARNING! If an electrical fuse blows, ensure that it is replaced with one of identical type and rating.

3

When the compressor is not in use, it should be switched off, isolated from the mains supply and the air drained from the tank.

Model No: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SACV42755B. . . . . . . . . . . . . . . . . . . . . . . . . SACV52775B

Motor Output: . . . . . . . . . . . . . . . . . . . . . . . . . . . .5.5hp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.5hp

Voltage/Phase: . . . . . . . . . . . . . . . . . . . . . . . . . . .415/3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 415/3

Rated Supply:. . . . . . . . . . . . . . . . . . . . . . . . . . . .16A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16A

Speed: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1270rpm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1280rpm

Air Displacement cfm(ltr/min): . . . . . . . . . . . . . . .21.1(600) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29.3(830)

Free Air Delivery cfm(ltr/min : . . . . . . . . . . . . . . . .16.9(480) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22.6(640)

Maximum Pressure: . . . . . . . . . . . . . . . . . . . . . . .145psi/10bar . . . . . . . . . . . . . . . . . . . . . . . . . . 145psi/10bar

Receiver Capacity: . . . . . . . . . . . . . . . . . . . . . . . .270ltr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270ltr

Dimensions: . . . . . . . . . . . . . . . . . . . . . . . . . . . . .770x 620 x 1710mm. . . . . . . . . . . . . . .770 x 620 x 1775mm

Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200kg

Heavy-duty three phase compressors suitable for the professional workshop. Two stage pump system coupled with a 3ph motor maximises

performance to keep running costs low compared to single stage single phase models. Pumps feature heavy-duty full cast cylinders, capped

by alloy heads for improved heat dissipation and long life. Heavy-duty drive guards protect belt and flywheel that is designed to force air over

the pump to aid cooling. Supplied with full CE certification, test certificates and operating/maintenance manual. Model No's SACV52775B and

SACV42755B have 270ltr vertical space saving tanks without compromising on volume.

Original Language Version

© Jack Sealey Limited

SACV42755B,ASACV45775B Issue: 1 - 17/12/14

Advertising