Introduction & specification, Operation, Fig.1 – Sealey SAC106B User Manual

Page 2

Advertising
background image

Original Language Version

SAC106B Issue: 3(SP) - 29/11/13

2. INTRODUCTION & SPECIFICATION

Manufactured from lightweight yet durable composite material with increased resistance to wear. Reduced weight eases manoeuvrability.

Suitable for general workshop applications. Oil free, single piston pump is driven by a 1.5hp motor inside the body, saving space around the

workshop. Fitted with fully automatic pressure cut-off switch and air regulator with gauge. Features integral handle. Simple construction with

fewer components makes this unit practically maintenance-free. Fitted with ASTA/BS approved non-rewirable plug.

3. OPERATION

WARNING! Ensure that you have read, understood and apply Section 1 safety instructions.

3.1.

The compressor should be located and operated in a position that allows good air circulation around the unit. Locate the compressor

in a convenient position for the work to be undertaken. Ensure that it is standing on a stable and level surface. Ensure the feet are in

direct contact with the surface.

3.2.

Attach the required air tool to the air outlet.

3.3.

Plug the mains plug into a mains electrical socket, but do not switch the compressor on until the workpiece and air tool are fully prepared.

3.4.

Switch on the unit by pushing the I/O switch in. To switch off press the switch again, it will spring out automatically on release.

3.5.

Pressure will build in the receiver until a pre-determined pressure of 8bar (116psi) is reached and the motor will automatically cut out.

3.6.

The output pressure can then be regulated by the pressure regulator knob. Adjust the pressure regulator knob to the pressure

required, which will be less than the receiver pressure. When the compressor is not being used, set the regulated pressure to zero to

avoid damaging the pressure reducer.

NOTE: a) If the motor does not cut in and out, but runs continuously when using an air appliance, the capacity of the compressor may be too

small for the tool being used.

b) The gauge on the left (fig.1) indicates the pressure inside the main tank. The gauge on the right (fig.1) indicates the regulated

pressure supplied to the air equipment. The pressure switch, not shown, stops the motor when the maximum tank pressure has

reached 8bar (116psi) and restarts it when the pressure falls below the minimum threshold - approximately 2 bar (29psi) less than the

maximum pressure.

WARNING! For this reason DO NOT remove fascia panel to tamper with, or adjust, the pre-set switch or safety valve.

c) Should there appear to be any loss of efficiency when using the compressor, ensure first that the air tool is clean and functioning

properly. If the air tool is satisfactory then refer to the trouble shooting guide.

Model No.: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SAC106B

Motor Output: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.5hp

Voltage/Phase: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230V - 1ph

Rated Supply:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5A

L

WA

(noise power level):. . . . . . . . . . . . . . . . . . . . . . . . .90dB(A)

Noise Pressure: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68dB(A)

Air Displacement cfm(ltr/min): . . . . . . . . . . . . . . . . . . . 5.6(160)

Maximum Free Air Delivery cfm(ltr/min): . . . . . . . . . . 1.47(41.6)

Receiver Capacity: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6ltr

Maximum Pressure: . . . . . . . . . . . . . . . . . . . . . . . . . 116psi/8bar

Overall Size (WxDxH): . . . . . . . . . . 350mm x 300mm x 440mm

Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10.8kg

Fig.1

Regulated

pressure gauge

Receiver

pressure gauge

Regulator

control knob

I/O Switch

To equipment

Drain valve

1200mm Lead length

© Jack Sealey Limited 2013

Kempson Way,

Bury St. Edmunds,

Suffolk, IP32 7AR

Code:

Serial no:

Max press: 8bar/116psi

In. pwr.: 1100W peak

Volt/Hz: 230/50-60/1

Itr/gal: 6/1.59

A 4 kg: 10.5

IP20 S3-30% min-1:2400

Out. pwr.: 0.5kw/0.67HP

Itr/min: 160 cfm: 5.6

Product label on underside

Advertising