Fig.1 fig.2, Air supply – Sealey AK456DX User Manual

Page 2

Advertising
background image

5. air sUpplY

the recommended hook-up is shown in fig.1.

5.1

ensure the air valve is in the "off" position before connecting to the air supply.

5.2

You will require an air pressure of 7bar.

5.3

WArnInG! ensure the air supply is clean and does not exceed pressures

specified in these Instructions. too high an air pressure and/or unclean air will

shorten the drainer life due to excessive wear, and may be dangerous, causing

damage and/or personal injury.

5.4

drain the air tank daily. Water in the air line may damage the drainer.

5.5

clean the air inlet filter screen weekly.

5.6

line pressure should be increased to compensate for unusually long air hoses

(over 8 metres).

the minimum hose diameter should be 10mm I.d. and fittings must have the same inside dimensions.

5.7

Keep hose away from heat, oil and sharp edges. check hoses for wear, and make certain that all connections are secure.

AK456dX Issue no.1 14/06/10

Original Language Version