Sealey TA126 User Manual

Current tester 30a, Ta126, Fig.1

Advertising
background image

INSTRUCTIONS FOR:

CURRENT TESTER 30A

MODEL NO:

TA126

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly

maintained, give you years of trouble free performance.

IMPORTANT PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS,

AND CAUTIONS. USE THIS PRODUCT CORRECTLY, AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO

DO SO MAY CAUSE DAMAGE, OR PERSONAL INJURY, AND WILL INVALIDATE THE WARRANTY.

p

WARNING! Suitable only for automotive circuits up to 48V DC.

Not suitable for domestic 110 - 230V applications.

Observe standard workshop safety procedures when using the tester.

p

WARNING! The Fuse blade may become hot during testing. Allow to cool before removing.

p

WARNING! DO NOT exceed Maximum Load: 30A/48V for Max 10sec.

Ensure vehicle ignition is switched

OFF before connecting or disconnecting TA126.

Keep the work area clean, uncluttered and ensure there is adequate lighting. Keep tools and other

items away from the engine, and ensure you can see the battery and working parts of engine clearly.

Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.

Remove ill fitting clothing. Remove ties, watches, rings and other loose jewellery. Contain or tie back

long hair.

Keep children and unauthorised persons away from the working area.

DO NOT disassemble. TA126 must be checked by qualified service personnel only.

DO NOT get the tester wet or use in damp or wet locations or areas where there is condensation.

DO NOT use the tester for any purpose other than for which it is designed.

DO NOT pull by the cables to free from the fuse terminals.

DO NOT operate TA126 if damaged.

When not in use store in a safe, dry, childproof location.

p

WARNING! The warnings, cautions and instructions referred to in this manual cannot cover all

possible conditions and situations that may occur. It must be understood that common sense and

caution are factors which cannot be built into this product, but must be applied by the operator.

1. SAFETY INSTRUCTIONS

2. INTRODUCTION / SPECIFICATION

Fast, accurate and safe current measurement at the

fuse box or battery. Ideal for fault-finding on car and

commercial vehicle electrical circuits. Features large

LCD display with numeric and bar-type functions.

Plugs directly into the vehicle’s fuse board. Supplied

with mini, standard adaptors and fused crocodile

clips. Compatible with alternative probes using the

standard Ø4mm banana adaptors.

Range: ....................... 0-30A - 0-48V

Accuracy: ................... ± 2%

Fuse Type: ................. Mini, Standard

Max Load: .................. 30A/48V for Max 10sec

Operating Temp: ........ 0°C to 50°C (32°F to 122°F)

Storage Temp: ........... -20°C to 60°C (-4°F to 140°F)

Relative Humidity: ...... <70% operating, <80% storage

Operating Altitude: ..... 7000ft (2000m) maximum

1. LCD Display

2. ZERO Button

3. HOLD Button

fig.1

4. Power On/Off Button

5. DATA Link

6. Clip Connector

7. Standard Blade Connector

8. MINI Blade Connector

9. Fuse Jack