3. SPECIFICATION

Function

Range

Resolution

Accuracy

DC Voltage

(V DC)

200mV

100µV

±(1.5% reading + 2 digits)

2000mV

1mV

20V

10mV

200V

100mV

1000V

1V

±(1.8% reading + 2 digits)

OVERLOAD PROTECTION: 220Vrms AC for 200mV range and 1000VDC or 750Vrms AC for other

ranges.

AC Voltage

(V AC)

200V

100mV

±(2% reading + 2 digits

(50/60Hz)

750V

1V

OVERLOAD PROTECTION: 1000 V DC or 750Vrms AC for all ranges.

RESPONSE: Average responding, calibrated in rms of a sine wave.

FREQUENCY RANGE: 45Hz - 450Hz

DC Current

(A DC)

200µA

100nA

±(2.0% reading + 2 digits)

2000 µA

1 µA

20mA

10µA

200mA

100µA

±(2.2% reading + 2 digits)

10A

10mA

±(2.0% reading + 2 digits)

OVERLOAD PROTECTION: 200mA /250V fuse (10A range unfused)

MEASURING VOLTAGE DROP: 200mV.

Resistance

200Ω

0.1Ω

±(1.8% reading + 5 digits)

2000Ω

1Ω

±(1.8% reading + 2 digits)

20kΩ

10kΩ

200kΩ

100Ω

2000kΩ

1kΩ

±(2% reading + 2 digits)

MAXIMUM OPEN CIRCUIT VOLTAGE: 2.8V

OVERLOAD PROTECTION: 15 seconds maximum 220Vrms on all ranges.

Diode Test

Display Voltage Drop Approximation

OVERLOAD PROTECTION: 15 seconds maximum 220Vrms Sounds alarm.

•)))

Audible Continuity

Built-in buzzer sounds if resistance is less than 100

OVERLOAD PROTECTION: 15 seconds maximum 220Vrms Sounds alarm.

hFE

Transistor hFE

Data Test

0 ~ 1000

Basic Current is Approx. 10µA., Vce is

Approx. 3V

Overload Protection: 10 seconds max. 220Vrms.

NOTE! Accuracy specifications consist of two elements:

(% reading) – This is the accuracy of the measurement circuit.

(+ digits) – This is the accuracy of the analog to digital converter.

NOTE! Accuracy is stated at 65°F to 83°F (18°C to 28°C) and less than 75% RH.

Safety: For indoor use and in accordance with Overvoltage Category II, Pollution Degree 2. Category II includes local level,

appliance, portable equipment, etc., with transient overvoltages less than Overvoltage Category III.

© Jack Sealey Limited

MM19.V3 Issue No: 5(I) - 16/06/14